Experimental dosimetry of a ~(32)P catheter-based endovascular brachytherapy source

机译:基于〜(32)P导管的血管内近距离放射治疗源的实验剂量测定

获取原文
获取原文并翻译 | 示例
           

摘要

The experimental dosimetry in a water phantom of a ~(32)P linear source, 20 mm in length, sued for the brachytherapy of coronary vessels is reported. The source content activity, A, was determined by means of a calibrated well ion-chamber and the value was compared with the contained activity reported in the manufacturer's certification. In this field of brachytherapy dosimetry, radiochromic film supplies a high enough spatial resolution. A highly sensitive radiochromic film, that presents only one active layer, was sued in this work for the source dosimetry in a water phantom. The radiochromic film was characterized by electron beams produced by a clinical linac. A Monte Carlo calculation of beta spectra in water at different distances along the source transverse bisector axis allowed to take into account the low dependence of film response from the electron beam energy. The adopted experimental setup, with the source in its catheter positioned on the film plane inside the water phantom, supplies accurate dosimetric information. The measured dose rate to water per unit of source activity at reference distances, D(r_0, θ_0)/A, in units of cGy s~(-1) GBq~(-1), was in agreement with the value reported in the manufacturer's certification within the experimental uncertainty. The radial dose function, g(r), is in good agreement with the literature data. The anisotropy function F(r, θ) is also reported. The analysis of the dose profile obtained at 2 mm from the source longitudinal axis shows that the uniformity is within 10% along 75% of the 20 mm treatment length. The adopted experimental set-up seems to be adequate for the quality control procedure of the dose homogeneity distribution in the water medium.
机译:据报道,在〜(32)P线性光源的水模型中,实验剂量法被用于冠状动脉的近距离放射治疗,长度为20 mm,用于线性治疗。通过校准的孔离子室测定源含量活性A,并将其与制造商认证中报告的所含活性进行比较。在近距离放射剂量学领域,放射致变色胶片提供了足够高的空间分辨率。在这项工作中,使用了仅具有一个活性层的高灵敏度放射致变色膜,用于水体模中的源剂量测定。放射致变色膜的特征在于临床直线加速器产生的电子束。沿源横向平分线轴在不同距离处的水中β光谱的蒙特卡洛计算,考虑到了薄膜响应与电子束能量之间的低依赖性。所采用的实验装置的导管中的水源位于水体模内部的胶片平面上,可提供准确的剂量信息。在参考距离D(r_0,θ_0)/ A处以单位cGy s〜(-1)GBq〜(-1)测得的单位源水对水的剂量率与报告中的值一致在实验不确定性范围内的制造商认证。径向剂量函数g(r)与文献数据非常吻合。还报告了各向异性函数F(r,θ)。对距放射源纵轴2 mm处获得的剂量分布的分析表明,沿着20 mm治疗长度的75%,均匀性在10%以内。所采用的实验设置似乎足以满足水介质中剂量均匀性分布的质量控制程序。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号