首页> 外文期刊>Physics in medicine and biology. >An indirect transmission measurement-based spectrum estimation method for computed tomography
【24h】

An indirect transmission measurement-based spectrum estimation method for computed tomography

机译:基于间接透射测量的计算机层析成像谱估计方法

获取原文
获取原文并翻译 | 示例
           

摘要

The characteristics of an x-ray spectrum can greatly influence imaging and related tasks. In practice, due to the pile-up effect of the detector, it's difficult to directly measure the spectrum of a CT scanner using an energy resolved detector. An alternative solution is to estimate the spectrum using transmission measurements with a step phantom or another CT phantom. In this work, we present a new spectrum estimation method based on indirect transmission measurement and a model spectra mixture approach. The estimated x-ray spectrum was expressed as a weighted summation of a set of model spectra, which can significantly reduce the degrees of freedom of the spectrum estimation problem. Next, an estimated projection was calculated with the assumed spectrum. By iteratively updating the unknown weights, we minimized the difference between the estimated projection data and the raw projection data. The final spectrum was calculated with these calibrated weights and the model spectra. Both simulation and experimental data were used to evaluate the proposed method. In the simulation study, the estimated spectra were compared to the raw spectra which were used to generate the raw projection data. For the experimental study, the ground truth measurement of the raw x-ray spectrum was not available. Therefore, the estimated spectrum was compared against the spectra generated using the SpekCalc software with tube configurations provided by the scanner manufacturer. The results show the proposed method has the potential to accurately estimate x-ray spectra using the raw projection data. The difference between the mean energy of the raw spectra and the mean energy of the estimated spectra was less than 0.5 keV for both the simulation and experimental data. Further tests show the method was robust with respect to the model spectra generator.
机译:X射线光谱的特征会极大地影响成像和相关任务。实际上,由于检测器的堆积效应,很难使用能量分辨检测器直接测量CT扫描仪的光谱。一种替代解决方案是使用带有阶跃模型或另一个CT模型的透射测量来估计频谱。在这项工作中,我们提出了一种基于间接透射测量和模型光谱混合方法的新光谱估计方法。估计的X射线光谱表示为一组模型光谱的加权总和,这可以显着降低光谱估计问题的自由度。接下来,利用假定的频谱计算估计的投影。通过迭代更新未知权重,我们将估算的投影数据与原始投影数据之间的差异最小化。使用这些校准砝码和模型光谱计算最终光谱。仿真和实验数据均用于评估该方法。在模拟研究中,将估计的光谱与用于生成原始投影数据的原始光谱进行比较。对于实验研究,无法获得原始X射线光谱的地面真相测量。因此,将估计的光谱与使用SpekCalc软件生成的光谱进行比较,该软件具有由扫描仪制造商提供的试管配置。结果表明,该方法具有利用原始投影数据准确估算X射线光谱的潜力。对于模拟和实验数据,原始光谱的平均能量与估算光谱的平均能量之间的差小于0.5 keV。进一步的测试表明,该方法相对于模型频谱生成器是可靠的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号