Dose and detectability improvements with high energy phase sensitive x-ray imaging in comparison to low energy conventional imaging

机译:与低能常规成像相比,高能相敏X射线成像的剂量和可检测性得到了改善

获取原文
获取原文并翻译 | 示例
           

摘要

The objective of this study was to demonstrate the potential benefits of using high energy x-rays for phase sensitive breast imaging through a comparison with conventional mammography imaging. We compared images of a contrast-detail phantom acquired on a prototype phase sensitive x-ray imaging system with images acquired on a commercial flat panel digital mammography unit. The phase contrast images were acquired using a micro-focus x-ray source with a 50 μ m focal spot at 120 kVp and 4.5 mAs, with a magnification factor of 2.46 and a 50 μ m pixel pitch. A phase attenuation duality-based phase retrieval algorithm that requires only a single phase contrast image was applied. Conventional digital mammography images were acquired at 27 kVp, 131 mAs and 28 kVp, 54 mAs. For the same radiation dose, both the observer study and signal-to-noise ratio (SNR)/figure of merit comparisons indicated a large improvement by the phase retrieved image as compared to the clinical system for the larger disc sizes, but the improvement was not enough to detect the smallest discs. Compared to the double dose image acquired with the clinical system, the observer study also indicated that the phase retrieved image provided improved detection capabilities for all disc sizes except the smallest discs. Thus the SNR improvement provided by phase contrast imaging is not yet enough to offset the noise reduction provided by the clinical system at the doubled dose level. However, the potential demonstrated by this study for high energy phase sensitive x-ray imaging to improve lesion detection and reduce radiation dose in mammography warrants further investigation of this technique.
机译:这项研究的目的是通过与常规乳腺X线摄影术成像比较,证明使用高能X射线进行相敏乳房成像的潜在好处。我们比较了在原型相敏X射线成像系统上获取的对比度细节体模的图像与在商用平板数字乳房X线照相设备上获取的图像。使用具有50μm焦点,120 kVp和4.5 mAs,放大倍数为2.46,像素间距为50μm的微焦点X射线源获取相衬图像。基于相位衰减对偶性的相位检索算法仅需要单个相位对比图像。在27 kVp,131 mAs和28 kVp,54 mAs下采集常规数字乳房X线照片。对于相同的辐射剂量,观察者研究和信噪比(SNR)/品质因数比较均表明,相较于较大的椎间盘,与临床系统相比,相位检索图像有很大的改善,但是改善了不足以检测最小的光盘。与通过临床系统获取的双剂量图像相比,观察者研究还表明,相恢复图像对于除最小的椎间盘以外的所有椎间盘大小均提供了改进的检测能力。因此,相衬成像所提供的SNR改善还不足以抵消临床系统在两倍剂量水平下所提供的降噪效果。然而,这项研究证明了高能相敏X射线成像在乳腺摄影中改善病变检测和减少放射剂量的潜力,值得对该技术进行进一步研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号