首页> 外文期刊>Physics in medicine and biology. >Independent verification of transferred delivery sinogram between two dosimetrically matched helical tomotherapy machines: A protocol for patient-specific quality assurance
【24h】

Independent verification of transferred delivery sinogram between two dosimetrically matched helical tomotherapy machines: A protocol for patient-specific quality assurance

机译:在两个剂量匹配的螺旋层析治疗机之间对转移的正弦图进行独立验证:针对特定患者的质量保证协议

获取原文
获取原文并翻译 | 示例
       

摘要

The purpose of this study was to independently verify the transferred delivery sinogram between two dosimetrically matched helical tomotherapy machines with the goal of eliminating redundant quality assurance (QA) measurements on the second machine. The equivalence of the two machines was evaluated based on both geometric and dosimetric beam characteristics, including measuring open field per cent depth doses (PDD), longitudinal and transverse profiles and helical delivery of clinical patient treatment plans measured in phantoms. QA of 56 patient plans was studied. The delivery sinogram on the secondary machine was computed by accounting for the differences in the MLC characteristics of the two machines. Computed sinograms were compared against the transferred sinograms by tomotherapy's data management system for the same 56 patient plans. The PDD, transverse and longitudinal dose profiles agreed within ±1% between the two machines. Ionization chamber and planar dose measurements with the Iba MatriXX device on both machines for the 56 patients were found to be within ±3% of the doses computed by the tomotherapy treatment planning system. For all 56 patients, the differences between computed sinograms and DMS-converted sinograms were within ±2%. The matched tomotherapy machines had similar beam characteristics. The sinogram-based QA was validated using point and planar dose measurements and found to be acceptable for clinical use.
机译:这项研究的目的是独立验证两台剂量匹配的螺旋断层摄影机之间的转移正弦图,目的是消除第二台机器上多余的质量保证(QA)测量。基于几何和剂量学射束特性评估了这两种机器的等效性,包括测量开放视野深度剂量(PDD),纵向和横向轮廓以及以幻影形式测量的临床患者治疗计划的螺旋输送。研究了56个患者计划的质量保证。通过考虑两台机器的MLC特性的差异,计算出二手机器上的输送正弦图。通过tomotherapy的数据管理系统,针对相同的56位患者计划,将计算出的正弦图与传输的正弦图进行了比较。两台机器之间的PDD,横向和纵向剂量分布在±1%之内。在两台机器上使用Iba MatriXX设备对56例患者进行的电离室和平面剂量测量,被发现在tomotherapy治疗计划系统计算的剂量的±3%之内。对于所有56例患者,计算的正弦图和DMS转换的正弦图之间的差异在±2%以内。匹配的tomotherapy机器具有相似的光束特性。基于点阵图的质量保证已通过点和平面剂量测量得到验证,并被临床接受。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号