The feasibility of exchange of blood plasma in a three-channel, countercurrent convective-mass exchange apparatus (CCMEA) has been theoretically considered. Fundamental advantages of CCMEA over a blood plasma filter have been noted. Calculations based on a mathematical model show a possibility of attaining a 90% or higher degree of CCMEA plasma exchange in the absence of blood thickening and almost at any flow rate of the blood drawn from and returned to the patient, including a low flow rate, which is very important in procedures of this kind.
机译:从理论上考虑了在三通道逆流对流质量交换装置(CCMEA)中进行血浆交换的可行性。已经注意到CCMEA相对于血浆过滤器的根本优势。根据数学模型进行的计算表明,在不存在血液增稠的情况下,以及几乎在任何从患者体内抽取和返回患者的血液流量(包括低流量)下,CCMEA血浆交换率都可能达到90%或更高程度,这在这种程序中非常重要。