...
首页> 外文期刊>Pediatric cardiology >A new method for evaluating tricuspid valve displacement in children with ebstein's anomaly: Using the annulus and coronary sinus as a reference point
【24h】

A new method for evaluating tricuspid valve displacement in children with ebstein's anomaly: Using the annulus and coronary sinus as a reference point

机译:ebstein异常患儿三尖瓣移位的一种新方法:以环和冠状窦为参考点

获取原文
获取原文并翻译 | 示例

摘要

This study aimed to investigate the reference point for the downward displacement of the posterior and anterior leaflets of the tricuspid valve using echocardiography in children with Ebstein's anomaly. This study enrolled 25 patients with Ebstein's anomaly. The extent of downward displacement of the posterior and anterior leaflets of the tricuspid valve was evaluated by echocardiography using the tricuspid annulus and the coronary sinus as reference points. These results were compared with the surgical findings. The findings showed displacement of the simple septal leaflet in 1 patient, displacement of both the septal and posterior leaflets in 22 patients, displacement of both the anterior and posterior leaflets in 1 patient, and displacement of all the leaflets in 1 patient. Because the septal and posterior leaflets were close to the apex or because the posterior leaflet was nearly absent, the displacement distance of the septal and posterior leaflets could not be measured accurately in two patients. The displacement distance of the septal and posterior leaflets in the remaining 22 patients were 2.08 ± 1.15 and 2.58 ± 1.06 cm, respectively. The displacement distances of the anterior leaflet in two patients were respectively 1.0 and 2.2 cm. These results were similar to those measured during surgery. The direction of the valvular regurgitation flow was anterolateral in the apical four-chamber and apical right heart two-chamber views in patients with the downward displacement of the anterior leaflet. The tricuspid valve annulus and the coronary sinus are ideal reference points for evaluating the downward displacement of the posterior and anterior leaflets of the tricuspid valve. It is critical to evaluate the downward displacement of the anterior leaflet that the direction of the tricuspid regurgitation flow is changed.
机译:本研究旨在探讨超声心动图检查对患有Ebstein异常儿童的三尖瓣后叶和前叶向下移位的参考点。该研究招募了25名患有Ebstein异常的患者。以三尖瓣环和冠状窦为参考点,通过超声心动图评估三尖瓣前后瓣的向下移位的程度。将这些结果与手术结果进行比较。研究结果表明,单纯中隔小叶移位1例,中隔小叶移位和后小叶移位22例,前后小叶移位1例,所有小叶移位1例。由于中叶和后叶都靠近根尖,或者因为后叶几乎不存在,所以无法准确测量两名患者中后叶和后叶的移位距离。其余22例患者中隔瓣和后瓣的移位距离分别为2.08±1.15和2.58±1.06 cm。两名患者前瓣的移位距离分别为1.0和2.2 cm。这些结果与手术期间测得的结果相似。对于前瓣向下移位的患者,在心尖四腔和心尖右心两腔视图中,瓣膜返流的方向为前外侧。三尖瓣环和冠状窦是评估三尖瓣后小叶和前小叶向下移位的理想参考点。评估三尖瓣反流的方向已改变,评估前瓣的向下移位是至关重要的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号