The Crab Nebula is one of the brightest and most stable sources in the X-ray sky. Year-scale flux variation from the object was recently revealed in the hard X-ray band by four satellites. This marked the first detection of year-scale variability from pulsar wind nebulae in the hard X-ray band. The Crab Nebula has been observed at least once a year for calibration purposes with the Suzaku Hard X-ray Detector (HXD) since its launch in 2005. In order to investigate possible spectral changes as well as flux variation, archival data of the HXD were analyzed. The flux variation reported by other instruments was confirmed in the 25-100 keV band by the HXD at a few percent level, but flux above 100 keV did not follow the trend in variation below 100 keV. The hardness ratios produced utilizing the PIN and GSO sensors installed in the HXD exhibit significant scattering, thereby indicating spectral variations in the hard X-ray band. The spectral changes were quantified by spectral fitting with a broken power-law model. The difference between the two photon indexes of the broken power-law model in harder and softer energy bands is in the range of <2.54. Taking into account a flux variation of 6.3% and a spectral variation time-scale of a few days, multi components of the broken power-law-shaped synchrotron emission with different cooling times are suggested.
机译:蟹状星云是X射线天空中最明亮,最稳定的源之一。最近有四颗卫星在硬X射线波段揭示了该物体的年尺度通量变化。这标志着首次从硬X射线波段的脉冲星云中检测出年尺度变化。自2005年投放以来,Suzaku硬X射线探测器(HXD)至少每年观测一次蟹状星云以进行校准。为调查可能的光谱变化以及通量变化,我们对HXD的档案数据进行了分析。分析。 HXD在25-100 keV波段确认了其他仪器报告的通量变化,误差在几个百分比水平,但高于100 keV的通量并没有遵循低于100 keV的变化趋势。利用安装在HXD中的PIN和GSO传感器产生的硬度比表现出明显的散射,从而表明硬X射线谱带中的光谱变化。光谱变化是通过使用折断的幂律模型进行光谱拟合来量化的。在较硬和较软的能带中,打破幂律模型的两个光子指数之间的差异在<2.54之内。考虑到6.3%的通量变化和几天的光谱变化时间尺度,建议在不同的冷却时间下,破碎的幂律型同步加速器发射的多个分量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号