We performed a prospective study of hospice in-patients requiring a syringe driver (SD), to determine the site duration and tolerability of metal butterfly needles compared to Teflon cannulae. Using patients as their own control, prescribed medications were divided equally between two SDs (Graseby MS16a), for delivery over 24 h. A butterfly infusion (Flosafer, 25 gauge) was connected to one SD and a Teflon cannula (Abbocath-T, 24 gauge), to the second. These were inserted subcutaneously (s.c.) on opposite sides of the body at comparable sites; oedematous, broken or painful sites were excluded. SD sites were examined at 4-hourly intervals. The study was terminated when both devices had required resiting. Needle and cannula times were compared using the Wilcoxon signed rank test. Thirty patients entered the study, 13 males and 17 females, mean age (standard deviation): 70 (11) years. Thirteen patients completed the study. Nine patients died and eight patients discontinued the study before both needle and cannula had been resited. All 30 patients are included in the analysis. The time from insertion to resiting of the cannula was significantly longer than the needle: P < 0.0002, median (range) 93.5 (22.8-263.5) h versus 42.8 (7.5-162.3) h, respectively. The cost of the needle versus cannula is 1.93 Pounds versus 2.51 Pounds, respectively. Teflon cannulae have a median life span twice that of metal butterfly needles and are a cost-effective alternative for administration of medications by s.c. infusion in terminally ill patients.
机译:我们对需要注射器驱动器(SD)的临终患者进行了一项前瞻性研究,以确定与Teflon套管相比,金属蝶形针的部位持续时间和耐受性。使用患者作为自己的对照,将处方药平均分配给两个SD(Graseby MS16a),分24小时分娩。将蝶形输注液(Flosafer,25号)连接至一个SD,将Teflon插管(Abbocath-T,24号)连接至第二个。将它们皮下(s.c.)插入人体相对侧的可比较位置;排除水肿,破裂或疼痛的部位。每4小时检查一次SD部位。当两个设备都需要重新放置时,研究终止。使用Wilcoxon符号秩检验比较针和套管的时间。 30名患者进入研究,男13例,女17例,平均年龄(标准差):70(11)岁。 13名患者完成了研究。九名患者死亡,八名患者在重新安置针头和套管之前中断了研究。所有30位患者均包括在分析中。从插入到重新放置套管的时间明显长于针头:P <0.0002,中位(范围)分别为93.5(22.8-263.5)h和42.8(7.5-162.3)h。针头与套管的成本分别为1.93磅对2.51磅。铁氟龙套管的中位寿命是金属蝶形针的两倍,是经皮下注射药物的经济有效的替代选择。输注绝症患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号