At blast furnace No 6 of the Russian Nizhnij Tagil Iron and Steel Works (NTMK) for the first time 4 m long copper staves were installed in the belly and lower stack and integrated in the evaporative cooling system (using only natural cooling water circulation - no pumps or secondary cooling). Additional measuring devices were installed to permit monitoring and analysis of the cooling system operation and the working parameters of the integrated copper staves. This paper evaluates the measured results and interprets the rationale for the use of copper staves in an evaporative cooling system.
机译:俄罗斯下塔吉尔钢铁厂(NTMK)的6号高炉首次在腹部和下部烟囱中安装了4 m长的铜冷却壁,并集成到蒸发冷却系统中(仅使用自然冷却水循环-否泵或二次冷却)。安装了附加的测量设备,以允许监视和分析冷却系统的运行以及集成铜冷却壁的工作参数。本文评估了测量结果,并解释了在蒸发冷却系统中使用铜冷却壁的原理。