首页> 外文期刊>Sleep & breathing =: Schlaf & Atmung >Perioperative practical experiences in using a level 2 portable polysomnography.
【24h】

Perioperative practical experiences in using a level 2 portable polysomnography.

机译:使用2级便携式多导睡眠监测仪的围手术期实践经验。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: The objective of the study is to test the hypothesis that a level 2 portable sleep device (Embletta X100) is a reliable alternative for standard PSG in surgical patients. METHODS: After hospital ethics approvals, preoperative patients over 18 years old were recruited. The patients for validation underwent standard PSG and Embletta X100 simultaneously in a sleep laboratory before surgery. The other patients received sleep studies with Embletta X100 perioperatively. The correlation analysis and paired Student t test between variables from Embletta and from standard PSG were used to evaluate the accuracy of Embletta. The quality of PSG recordings with Embletta was summarized. RESULT: Twenty-one patients completed sleep study on both systems; ten females and ten males, age was 54 +/- 11 and BMI was 36 +/- 9. There was a significant correlation between the majority of parameters from standard PSG and Embeltta X100 with manual scoring. The inter-rater agreement was substantial to perfect at different AHI cutoffs with a Kappa coefficient of 0.69 to 1. A significant correlation between standard PSG and Embletta X100 with automatic scoring was found only in AHI and a few other parameters. In 385 patients, 1,002 perioperative PSG recordings were carried out with Embletta. Of them, 889(88.7%) were technically good and 90(9%) technically acceptable. Only 23 (2.3%) PSG recordings failed. CONCLUSION: Embletta X100, installed by a well-trained sleep technician, is a good alternative when standard PSG was not available or impractical. Manual scoring by a certified PSG technologist is the key for reliable results.
机译:目的:本研究的目的是检验以下假设:2级便携式睡眠设备(Embletta X100)是外科患者中标准PSG的可靠替代品。方法:在医院伦理学批准后,招募了18岁以上的术前患者。接受验证的患者在手术前在睡眠实验室中同时接受标准PSG和Embletta X100。其他患者在围手术期接受了Embletta X100的睡眠研究。来自Embletta和标准PSG变量之间的相关分析和成对的Student t检验用于评估Embletta的准确性。总结了Embletta的PSG录音质量。结果:21例患者完成了两个系统的睡眠研究; 10位女性和10位男性,年龄为54 +/- 11,BMI为36 +/-9。标准PSG和Embeltta X100的大多数参数与手动评分之间存在显着相关性。评分员之间的协议在不同的AHI临界值上具有很强的完善性,其Kappa系数为0.69:1。只有在AHI和其他一些参数中,标准PSG与具有自动评分功能的Embletta X100之间才存在显着相关性。在385例患者中,使用Embletta进行了1,002例围手术期PSG记录。其中,889(88.7%)的技术状况良好,而90(9%)的技术状况可接受。 PSG录制仅23次(2.3%)失败。结论:当没有标准PSG或不可行时,由受过良好训练的睡眠技术人员安装的Embletta X100是一个不错的选择。由可靠的PSG技术人员手动评分是获得可靠结果的关键。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号