Lead-induced tricuspid stenosis--successful management by balloon angioplasty.

机译:铅诱发的三尖瓣狭窄-通过球囊血管成形术成功治疗。

获取原文
获取原文并翻译 | 示例
           

摘要

We describe a case of tricuspid stenosis in a young woman 11 years after endocardial ventricular lead implantation. The cause of the stenosis appears to have been perforation of the septal leaflet by the lead at the time of insertion. We further describe successful management with percutaneous balloon valvuloplasty without the need for lead removal.
机译:我们描述了一名心内膜心室铅植入术后11年的年轻女性三尖瓣狭窄的病例。狭窄的原因似乎是插入时导线导致间隔小叶穿孔。我们进一步描述了经皮球囊瓣膜成形术的成功管理,而无需去除铅。