首页> 外文期刊>PACE: Pacing and clinical electrophysiology >Successful radiofrequency catheter ablation of ventricular tachycardia originating from underneath the mechanical prosthetic aortic valve.
【24h】

Successful radiofrequency catheter ablation of ventricular tachycardia originating from underneath the mechanical prosthetic aortic valve.

机译:成功的射频导管消融源自机械性人工主动脉瓣膜下方的室性心动过速。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A 67-year-old man who developed sustained ventricular tachycardia (VT) 4 years after a prosthetic aortic valve replacement, underwent electrophysiologic testing and catheter ablation. The mechanism of the VT was suggested to be triggered activity because the VT could be induced by programmed ventricular stimulation, and burst ventricular pacing demonstrated overdrive suppression without a transient entrainment. Successful catheter ablation using a transseptal approach was achieved underneath the mechanical prosthetic aortic valve on the blind side for that approach. This case demonstrated that catheter mapping and ablation of the entire LV using a transseptal approach might be possible.
机译:一位67岁的男子在人工主动脉瓣置换术后4年出现持续性室性心动过速(VT),接受了电生理测试和导管消融。提示VT的机制是触发活动的,因为VT可以通过程序性的心室刺激来诱发,并且突发性心室起搏显示出过度驱动抑制作用,而没有短暂的夹带。在这种方法的盲侧机械性人工主动脉瓣膜之下,使用经隔方法成功地消融了导管。该病例表明,采用经隔隔入路的导管定位和消融整个左室是可能的。