...
首页> 外文期刊>PACE: Pacing and clinical electrophysiology >Sensitivity of transesophageal electrophysiologic study in children with supraventricular tachycardia on electrocardiography
【24h】

Sensitivity of transesophageal electrophysiologic study in children with supraventricular tachycardia on electrocardiography

机译:小儿室上性心动过速经食管电生理研究的敏感性

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction The aim of this study was to evaluate the inducibility of tachycardia by transesophageal electrophysiologic study (TEEPS) in patients with documented supraventricular tachycardia (SVT) on electrocardiography and to investigate the accuracy of TEEPS records by comparing with intracardiac electrophysiologic study (IEPS). Material and Methods The TEEPS records of patients having documented electrocardiography during SVT were reviewed. The results of TEEPS in 43 of 85 patients were compared with results of IEPS for compatibility of diagnosis. Results A total 85 patients, 46 male and 39 female, mean weight 35.1 kg (36-87), aged 1 month-17 years, were included. Tachycardia was induced by TEEPS in 79 of 85 patients with documented electrocardiography (sensitivity 92.9%). IEPS for diagnosis or ablation was conducted in 40 patients having inducible tachycardia and three of six who had no inducible tachycardia by TEEPS. Tachycardia was induced by IEPS in 39 of 40 (97.5%) patients who had inducible tachycardia and two of three who had no inducible tachycardia by TEEPS. Mechanisms of tachycardias were similar in 97.5% of patients (37/39) who had inducible tachycardia in TEEPS and IEPS. One of the patients with atrioventricular reentry tachycardia by TEEPS was diagnosed as atrioventricular nodal reentry tachycardia (AVNRT) and the other one was diagnosed as atypical AVNRT and atrial tachycardia by IEPS. Conclusion The rates of inducibility and mechanisms of tachycardias by TEEPS in children having documented SVT were similar with those obtained from IEPS.
机译:引言这项研究的目的是通过经食道电生理研究(TEEPS)对经心电图记录的室上性心动过速(SVT)的患者评估心动过速的发生率,并通过与心脏内电生理研究(IEPS)进行比较来研究TEEPS记录的准确性。材料和方法回顾了SVT期间已记录心电图的患者的TEEPS记录。将85例患者中的43例的TEEPS结果与IEPS的结果进行比较,以进行诊断。结果共纳入85例患者,男46例,女39例,平均体重35.1 kg(36-87),年龄1个月至17岁。有心电图记录的85例患者中有79例由TEEPS诱发了心动过速(敏感性为92.9%)。对40例可诱导性心动过速患者和6例中无3例经TEEPS不能诱导的心动过速进行IEPS诊断或消融。 IEPS诱发40例(97.5%)诱发性心动过速患者中的心动过速,TEEPS无诱发性心动过速的三分之二。 97.5%(37/39)的TEEPS和IEPS诱导型心动过速患者的心动过速机制相似。 TEEPS将一名房室折返性心动过速诊断为房室结性折返性心动过速(AVNRT),另一名被IEPS诊断为不典型的AVNRT和房性心动过速。结论TEEPS诱发SVT患儿心动过速的发生率和机制与IEPS相似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号