首页> 外文期刊>PACE: Pacing and clinical electrophysiology >Exercise induced atrioventricular block with gap phenomenon in atrioventricular conduction.
【24h】

Exercise induced atrioventricular block with gap phenomenon in atrioventricular conduction.

机译:运动引起的房室传导阻滞,在房室传导中存在间隙现象。

获取原文
获取原文并翻译 | 示例
           

摘要

A 54-year-old man with normal atrioventricular (AV) conduction at rest gave a 4-year history of presyncope during exercise. Treadmill testing showed exercise induced AV block. Electrophysiological study demonstrated rate dependent infranodal AV block and abnormal refractory period of the His-Purkinje system. The gap phenomenon in AV conduction occurred during the programmed stimulation. Supernormal conduction could be considered as the mechanism of the gap phenomenon in this patient.
机译:一名54岁休息时房室(AV)传导正常的男子在运动期间有4年的晕厥前病史。跑步机测试显示运动引起的房室传导阻滞。电生理研究表明,率依赖性的下层房室传导阻滞和His-Purkinje系统的异常不应期。在程序性刺激过程中发生了AV传导的间隙现象。超导可能被认为是该患者间隙现象的机制。