首页> 外文期刊>PACE: Pacing and clinical electrophysiology >Percutaneous transcatheter repositioning of displaced permanent pacemaker lead.
【24h】

Percutaneous transcatheter repositioning of displaced permanent pacemaker lead.

机译:经皮置入的永久性起搏器导线经导管复位。

获取原文
获取原文并翻译 | 示例
           

摘要

In three patients, two with a pacemaker and one with an implantable cardioverter defibrillator, hospitalized for dislodgement of a passive fixation J-shaped atrial lead, a percutaneous transcatheter repositioning was successfully attempted thus avoiding surgical revision. This procedure, performed through the femoral vein, is easy and safe. The stability of the lead position and of the pacing and sensing parameters was confirmed 1 and 6 months after the transcatheter repositioning.
机译:在三名患者中,两名因起搏器起搏,另一名因植入式心脏复律除颤器而住院,因为该患者因被动固定J形心房导线的移位而住院,成功地尝试了经皮经皮导管置入术,从而避免了手术翻修。通过股静脉进行的这一过程既简单又安全。经导管重新定位后1和6个月,确认了导联位置以及起搏和传感参数的稳定性。