摘要

I would like to point out a substantial inaccuracy in the article "Managing chronic pain: results from an open-label study using MC5-A Calmare~R device in Support Care Cancer", 11 March 2011. The authors correctly highlighted the operator-dependent variable (correct electrode positioning) in the methodology that can have a meaningful impact on the study. In a nutshell, correct electrode-positioning results in immediate zero pain and no unpleasant sensations by the patient. Zero pain during the stimulation determines the treatment cycle output result and follow-up, and thus is an extremely critical parameter. In order to render sufficiently homogenous the electrode-positioning methodology and scientifically compare the data emerging from different clinical studies, from 2002 a standard method has been created and tested at length [1, 2], and seem to meet the goal.
机译:我想在2011年3月11日的文章“管理慢性疼痛:使用MC5-A Calmare〜R设备在支持性护理癌症中进行的开放标签研究的结果”中指出严重错误。作者正确强调了依赖于操作者的方法中的变量(正确的电极位置)可能会对研究产生有意义的影响。简而言之,正确的电极位置可导致患者立即零痛且无不适感。刺激过程中的零疼痛决定了治疗周期的输出结果和随访,因此是一个非常关键的参数。为了使电极定位方法足够均匀并科学地比较不同临床研究中得到的数据,从2002年开始,一种标准方法已经建立并在长度[1,2]上进行了测试,似乎可以达到目标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号