The presence and description of anatomical findings about the foramen of Vesalius (FV) is important in the surgical procedure on the trigeminal nerve and/or trigeminal ganglion. This is an evaluation area for percutaneous techniques. A morphological analysis of the FVs was made in a total of 344 sides of the basis cranii of adult skulls by computerized photogrammetry using standardized digital photographs. The FV was identified in 60 specimens (34.8 %). The FV was observed to be present bilaterally in 16 specimens (9.3 %). The incidence of unilateral FV was 25.5 % of the skulls, of which in 26 specimens (15.1 %) it occurred on the left side, and in 18 specimens (10.4 %) on the right side. The FV was observed to present a double opening in two specimens. The diameters of the FV were found to be 0.86 ± 0.21 (right) and 1.07 ± 0.37 mm (left). The incidence of openings with a diameter of FV 0.5 mm or more was found to be 45 %. The area of the FV was calculated as 1.09 ± 0.51, and 1.4 ± 0.83 mm2 on the right and the left, respectively. The mean distances of FV to the foramen ovale were measured as 2.30 ± 1.14 mm (right) and 2.46 ± 0.89 mm (left). The mean distances of FV to foramen spinosum were found to be 10.76 ± 1.26 mm (right) and 10.42 ± 1.29 mm (left). The findings suggest that the diameter of FV as 0.5 mm was safer to work with, while the opening types bigger than 0.5 mm opening types were highly risky for percutaneous techniques on the foramen ovale. In our study, a clear standardization has been achieved. The findings were the data obtained through computer-assisted three dimensional landmarks, appropriate for use in three dimensional planning.
机译:在三叉神经和/或三叉神经节的外科手术中,有关Vesalius(FV)孔的解剖发现的存在和描述很重要。这是经皮技术的评估领域。通过计算机摄影测量法,使用标准化的数字照片,在成年头骨基础颅骨的总共344个侧面中对FV进行了形态学分析。在60个样本中检出FV(34.8%)。观察到FV双向出现在16个样本中(9.3%)。单侧FV的发生率占颅骨的25.5%,其中在左侧的26个标本(15.1%)中发生,在右侧的18个标本中占10.4%。观察到FV在两个样本中呈现出双重开口。发现FV的直径为0.86±0.21(右)和1.07±0.37 mm(左)。发现直径为FV 0.5 mm或更大的开口占45%。 FV的面积分别在右侧和左侧分别为1.09±0.51和1.4±0.83 mm2。 FV至卵圆孔的平均距离测得为2.30±1.14 mm(右)和2.46±0.89 mm(左)。 FV到棘突孔的平均距离为10.76±1.26 mm(右)和10.42±1.29 mm(左)。研究结果表明,直径小于0.5毫米的FV直径更安全,而大于0.5毫米的开口类型则对卵圆孔的经皮技术具有很高的风险。在我们的研究中,已经实现了明确的标准化。研究结果是通过计算机辅助的三维界标获得的数据,适用于三维规划。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号