This study was designed to assess the safety, efficacy, and postoperative outcomes of partial stapled hemorrhoidopexy (PSH).A prospective study was conducted between February and March 2010. PSH was performed with single-window anoscopes for single isolated hemorrhoids, bi-window anoscopes for two isolated hemorrhoids, and tri-window anoscopes for three isolated hemorrhoids or circumferential hemorrhoids. The data pertaining to demographics, preoperative characteristics and postoperative outcomes were collected and analyzed.Forty-four eligible patients underwent PSH. Single-window anoscopes were used in 2 patients, and bi- and tri-window anoscopes in 6 and 36 patients. The blood loss in patients with single-window, bi-window, and tri-window anoscopes was 6.0?ml (range 5.0-7.0?ml), 5.0?ml (range 5.0-6.5?ml), and 5.0?ml (4.5-14.5?ml) (P?=?0.332). The mean postoperative visual analog scale score for pain was 3 (range, 1-4), 2 (range 1-4), 3 (range 2-6), 1 (range 0-3), 1 (range 0-2) and 2 (range 2-4) at 12?h, days 1, 2, 3, and 7, and at first defecation. The rate of urgency was 9.1%. No patients developed anal incontinence or stenosis. The 1-year recurrence rate of prolapsing hemorrhoids was 2.3%.Partial stapled hemorrhoidopexy appears to be a safe and effective technique for grade III-IV hemorrhoids. Encouragingly, PSH is associated with mild postoperative pain, few urgency episodes, and no stenosis or anal incontinence.
展开▼