首页> 外文期刊>Surgical and radiologic anatomy : >Variations of pelvic anteversion in the lying and standing positions: analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup.
【24h】

Variations of pelvic anteversion in the lying and standing positions: analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup.

机译:卧位和站立位的骨盆前倾变化:24位对照对象的分析及其对假体杯位置的CT测量的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

The position of the acetabular implant plays a dominant role in the displacement of a total hip prosthesis. CT allows precise measurement of the position of the cup, but the influence of pelvic rotation on this measurement is unknown. The aim of this study was to determine, in a group of healthy subjects, whether a pelvic equilibrium exists specific to each individual, and whether this is constant over time on the one hand and between the standing and lying positions on the other. The study concerned 15 men and 9 women with a mean age of 31 years. Each subject had strictly lateral radiographs of the pelvis, lying and standing, repeated at two different times. Pelvic version was measured in these radiographs. Each individual had a pelvic position constant over time, both in the lying and standing positions. However, there were important variations of the position of the pelvis during passage from the lying to the standing position: 22 patients had retroversion of the pelvis by a mean of 7 degrees (2-18 degrees) and 2 others had an anteversion of 3 degrees. These major variations of the pelvic position between the standing and lying positions explain why CT studies made in the lying position do not allow for the anteversion of the cup in the standing position, which is close to the dynamic situation during which displacement may occur. Thus, an excessive anteversion of the cup may be masked when the scan is made in the lying position, since in this position the anteversion of the pelvis leads to retroversion of the cup. The error may reach 20 degrees, so that we recommend that CT measurements made without allowing for the position of the pelvis should be interpreted with caution.
机译:髋臼假体的位置在整个髋关节假体的移位中起主要作用。 CT可以精确测量杯的位置,但是盆腔旋转对此测量的影响尚不清楚。这项研究的目的是确定一组健康受试者中是否存在每个人特定的骨盆平衡,以及一方面该平衡是否随时间变化以及另一方面是否处于站立和卧姿之间。该研究涉及15名男性和9名女性,平均年龄为31岁。每个受试者的骨盆侧面和侧面都有严格的X光片,分别在两个不同的时间重复。在这些射线照相中测量了骨盆的版本。每个人的坐姿和坐姿都随时间变化。但是,在从躺卧到站立的过程中,骨盆的位置存在重要变化:22例患者的骨盆后倾平均为7度(2-18度),另2例患者的前倾度为3度。站立位置和躺着位置之间的骨盆位置的这些主要变化解释了为什么在躺着位置进行的CT研究不允许杯在站立位置前倾,这与可能发生位移的动态情况很接近。因此,当在躺卧位置进行扫描时,罩杯的过度前倾可能被掩盖,因为在该位置骨盆的前倾导致杯的后倾。误差可能会达到20度,因此我们建议在考虑骨盆位置的情况下进行CT测量应谨慎。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号