...
首页> 外文期刊>Surgical innovation >Evaluation of acute fixation strength for mechanical tacking devices and fibrin sealant versus polypropylene suture for laparoscopic ventral hernia repair.
【24h】

Evaluation of acute fixation strength for mechanical tacking devices and fibrin sealant versus polypropylene suture for laparoscopic ventral hernia repair.

机译:评估机械固定装置和纤维蛋白密封剂相对于聚丙烯缝合线的腹腔镜腹疝修补术的急性固定强度。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The purpose of this comparative study is to evaluate the acute fixation strength of mechanical tacking devices and fibrin sealant against polypropylene suture for laparoscopic ventral hernia repair. METHODS: Three metallic mechanical tacking devices (ProTack, Salute, EndoANCHOR), 4 absorbable tacking devices (AbsorbaTack, PermaSorb, I-Clip, and SorbaFix), and 2 types of fibrin sealant (Tisseel, Artiss) were compared with 0-polypropylene suture. Three constructs from each device or an amount of sealant sufficient to cover a 3 x 3 cm(2) area were used to affix a 4 x 3 cm piece of absorbable barrier-coated mesh (Proceed, Ethicon, Inc) to the peritoneal surface of porcine abdominal wall. Ten samples were completed for each fixation modality. Acute fixation strength was measured via a lap shear test on an Instron tensiometer. RESULTS: Acute fixation strength was significantly greater for suture (59.7 7.2 N) compared with all laparoscopic tacking devices and to fibrin sealant (P < .001 for all comparisons). Protack (29.5 +/- 2.8 N) was stronger than Absorbatack (13.2 +/- 3.7 N; P = .029). Protack, Permasorb, SorbaFix, and I-clip were stronger than fibrin sealant (P < .05 for all comparisons). CONCLUSIONS: The acute fixation strengths of metallic or absorbable tacks as well as fibrin sealant are all significantly less than that achieved with polypropylene suture. These factors should be considered in selecting the type of mechanical fixation for patients undergoing laparoscopic ventral hernia repair.
机译:背景:这项比较研究的目的是评估腹腔镜腹疝修补术的机械固定装置和纤维蛋白密封剂对聚丙烯缝合线的急性固定强度。方法:比较了三种金属机械粘扣装置(ProTack,Salute,EndoANCHOR),4种可吸收粘扣装置(AbsorbaTack,PermaSorb,I-Clip和SorbaFix)和两种类型的纤维蛋白密封剂(Tisseel,Artiss)与0聚丙烯缝合线的比较。 。每个设备的三个结构或足以覆盖3 x 3 cm(2)区域的一定数量的密封剂用于将一块4 x 3 cm的可吸收的阻隔涂层网片(Proceed,Ethicon,Inc)固定到腹膜表面。猪腹壁。每个固定方式完成十个样本。通过在Instron张力计上的搭接剪切测试来测量急性固着强度。结果:与所有腹腔镜增粘器械和纤维蛋白密封剂相比,缝线的急性固定强度(59.7 7.2 N)明显更高(所有比较的P <0.001)。 Protack(29.5 +/- 2.8 N)比Absorbatack(13.2 +/- 3.7 N; P = .029)强。 Protack,Permasorb,SorbaFix和I-clip比纤维蛋白密封剂强(所有比较的P <0.05)。结论:金属或可吸收粘性材料以及纤维蛋白密封剂的急性固定强度均明显低于聚丙烯缝合线。在为腹腔镜腹侧疝修补术患者选择机械固定类型时应考虑这些因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号