BACKGROUND: Passing an instrument through a small incision alters the kinematics of the instrument, thus hampering hand-eye coordination. Nevertheless, the incision provides a stable, nearly invariant, point of rotation for instrument movements. Therefore, we set out to evaluate the effects of the altered kinematics on hand-eye coordination. In addition, we assessed the hypothesis that the hand-eye coordination of laparoscopic surgeons incorporates the incision as a point of reference. METHODS: Eight surgeons with experience in laparoscopy repeatedly performed a positioning task on a two-dimensional endoscopic manipulation simulator. Task time was measured. In the first experiment, normal endoscopic manipulation was compared to a condition in which the kinematic effects of the incision were compensated for. In the second experiment, the instrument shaft on the monitor was not visible during half of the trials, so that all visual information about the location of the incision was obscured. RESULTS: Task performance improved significantly when the kinematic effects of the incision were compensated for (p = 0.001). Task performance improved when the instrument shaft was clearly visible on the monitor (p <0.05). CONCLUSIONS: Compensating for the kinematic effects introduced by the incision improves hand-eye coordination. The results of this study indicate that the incision provides a point of reference for hand-eye coordination during endoscopic manipulation.
机译:背景:将器械通过小切口会改变器械的运动学,从而妨碍手眼协调。然而,切口为器械运动提供了稳定的,几乎不变的旋转点。因此,我们着手评估运动学变化对手眼协调的影响。此外,我们评估了以下假设:腹腔镜外科医生的手眼协调将切口作为参考。方法:八位具有腹腔镜检查经验的外科医生在二维内窥镜操作模拟器上反复执行了定位任务。测量任务时间。在第一个实验中,将正常的内窥镜操作与补偿了切口运动学效果的条件进行了比较。在第二个实验中,在一半的试验中,监视器的仪器轴不可见,因此有关切口位置的所有视觉信息都被遮盖了。结果:补偿了切口的运动学效果后,任务执行能力显着提高(p = 0.001)。当仪器轴在监视器上清晰可见时,任务性能得到改善(p <0.05)。结论:补偿切口引起的运动学影响可改善手眼协调性。这项研究的结果表明,该切口为内窥镜操作期间的手眼协调提供了参考。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号