BACKGROUND: Despite widespread acknowledgement that strain injuries do occur to surgeons, ergonomic assessments in minimally invasive surgery are comparatively rare. Current assessment techniques rely on labor-intensive manual recording techniques, so there is a need for an automated system. METHODS: We used an optoelectronic measurement system to make postural measurements at frequencies of ~5 Hz and then converted these measurements to ergonomic stress scores using a modified Rapid Upper Limb Assessment (RULA) method. RESULTS: We successfully recorded postures at least once per second during 96% of the time the surgeon was performing tissue manipulation tasks. We found that the ergonomic stress scores were comparatively high throughout the procedure, particularly for the wrist. CONCLUSION: An automated high-frequency postural measurement system is feasible for making ergonomic assessments in an intraoperative setting. Such a system will also be a critical component in validating surgical simulations for use in training and credentialing surgeons and in designing and evaluating equipment.
机译:背景:尽管普遍承认外科医生确实会发生劳损,但在微创手术中进行人体工程学评估的情况相对较少。当前的评估技术依赖于劳动密集的手动记录技术,因此需要自动化系统。方法:我们使用光电测量系统以〜5 Hz的频率进行姿势测量,然后使用改进的快速上肢评估(RULA)方法将这些测量值转换为人体工程学应力评分。结果:在外科医生执行组织操作任务的96%的时间内,我们至少每秒成功记录一次姿势。我们发现在整个过程中,特别是对于手腕,人体工程学压力评分相对较高。结论:自动化的高频姿势测量系统对于在术中进行人体工程学评估是可行的。这样的系统也将是验证用于训练和认证外科医生以及设计和评估设备的手术模拟的关键组成部分。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号