首页> 外文期刊>Strabismus >Correlation between depth perception by three-rods test and stereoacuity by distance randot stereotest
【24h】

Correlation between depth perception by three-rods test and stereoacuity by distance randot stereotest

机译:三杆测试的深度知觉与距离兰特立体测试的立体视力之间的相关性

获取原文
获取原文并翻译 | 示例
       

摘要

Background: The examination of depth perception with three-rods test, in addition to visual acuity testing, is required to obtain motor vehicle license to drive taxies and trucks, according to the Road Traffic Act in Japan. The aim of this study was to examine whether the results of the three-rods test would correlate with the results of static stereopsis tests, used in ophthalmic practice. Methods: This study involved 54 normal subjects, 9 women and 45 men, with ages ranging from 18 to 25 (mean, 20.8) years. All had visual acuity of 0.8 or better with or without glasses or contact lenses correction and had no strabismus at the distant (5m) or near (0.3m) fixation. TNO Stereotest and Titmus Stereotest were examined at 40cm while Distance Randot Stereotest was at 3m. At three-rods test, a central rod was moved at the speed of 50mm/sec forward and backward automatically against two laterally located fixed rods, placed inside the illuminated box. An examinee at the distance of 2.5m observed the rods inside the box from a small viewing window and pushed a button to stop the central rod in alignment with the fixed rods. Erred distance (mm) of the central rod from the fixed rods as a mean of 4 measurements was correlated with stereoacuity in second of arc, measured by three kinds of the stereopsis tests. Results: The erred distance of three-rods test was positively correlated with static stereoacuity at distance measured with Distance Randot Stereotest (ρ=0.418, p=0.0023, Spearman rank correlation test) and also with the other stereopsis tests at near fixation. The stereoacuity at near fixation, measured by TNO Stereotest and Titmus Stereotest, was positively correlated with each other (ρ=0.431, p=0.0017). Conclusion: Three-rods test, examining depth perception, together with the response by eye-hand coordination, gave consistent results with distant static stereoacuity when measured with Distance Randot Stereotest.
机译:背景:根据日本的《道路交通法》,除视力测试外,还需要通过三杆测试对深度知觉进行检查,以获得驾驶出租车和卡车的机动车牌照。这项研究的目的是检查三杆测试的结果是否与眼科实践中使用的静态立体视觉测试的结果相关。方法:本研究涉及54名正常受试者,9名女性和45名男性,年龄在18至25(平均20.8)岁之间。不论是否配戴眼镜或不戴隐形眼镜,所有患者的视力均为0.8或更高,并且在远距(5m)或近距(0.3m)固定时均无斜视。在40cm处检查TNO Stereotest和Titmus Stereotest,而距离Randot Stereotest在3m处。在三杆测试中,中心杆以50mm / sec的速度自动向前和向后移动,抵靠放置在照明箱内的两个侧向固定杆。距离2.5m的一位考生从一个小观察窗观察盒子内的杆,并按下按钮以使中心杆与固定杆对齐。中心杆距固定杆的误差距离(mm)(以4次测量的平均值表示)与以三种弧度测试测得的秒弧度的立体角相关。结果:三杆测试的错误距离与距离立体兰特立体测试(ρ= 0.418,p = 0.0023,Spearman等级相关性测试)测得的距离和其他立体视测试在固定时的正立体感呈正相关。通过TNO Stereotest和Titmus Stereotest测量的近固定时的立体视力彼此呈正相关(ρ= 0.431,p = 0.0017)。结论:三杆测试可以检查深度知觉,并通过手眼协调做出响应,在用距离Randot立体测试进行测量时,可以得到与远距离静态立体视力一致的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号