This paper deals with spectral interferences of complex matrix containing Mo, Al, Ti, Fe, Mg, Ca and Cu in the determination of rhenium in molybdenum and copper concentrates by inductively coupled plasma optical emission spectrometry (ICP-OES). By radial viewing 40.68 MHz ICP equipped with a high resolution spectrometer (spectral bandwidth = 5 pm) the hyperfine structure (HFS) of the most prominent lines of rhenium (Re II 197.248 nm, Re II 221.426 nm and Re II 227.525 nm) was registered. The HFS components under high resolution conditions were used as separate prominent line in order to circumvent spectral interferences. The Q-concept was applied for quantification of spectral interferences.
机译:本文通过电感耦合等离子体发射光谱法(ICP-OES)处理钼,铝,钛,铁,镁,钙和铜的复杂基质在测定钼和铜精矿中of时的光谱干扰。通过径向观察配有高分辨率光谱仪(光谱带宽= 5 pm)的40.68 MHz ICP,记录了registered最显着谱线(Re II 197.248 nm,Re II 221.426 nm和Re II 227.525 nm)的超精细结构(HFS)。 。为了避免频谱干扰,将高分辨率条件下的HFS组件用作单独的突出显示线。 Q概念用于量化光谱干扰。