首页> 外文期刊>Spectrochimica Acta, Part B. Atomic Spectroscopy >Hydride generation-electrostatic deposition-graphite furnace atomic absorption spectrometric determination of arsenic, selenium and antimony
【24h】

Hydride generation-electrostatic deposition-graphite furnace atomic absorption spectrometric determination of arsenic, selenium and antimony

机译:氢化物发生-静电沉积-石墨炉原子吸收光谱法测定砷,硒和锑

获取原文
获取原文并翻译 | 示例

摘要

A system is described and evaluated for the in situ collection of generated hydrides of As, Se and Sb in a graphite furnace using a high voltage electrostatic field. Analytical figures of merit are derived using graphite furnace atomic absorption detection and a characterization of the electrostatic deposition (ED) process is presented based on optimization studies. Absolute detection limits (LOD) of 30, 16 and 33 pg were obtained for As, Se and Sb, respectively, reflecting overall generation / collection efficiencies of 80 +- 5, 71 +- 3 and 62 +- 6%, respectively. Precision of replicate determination was typically 4% R. S. D. at a concentration 40-fold above the LOD for a 1 ml sample volume. The accuracy of the approach was demonstrated through the analysis of coastal seawater and marine sediment certified reference materials.
机译:描述并评估了使用高压静电场在石墨炉中原位收集生成的As,Se和Sb氢化物的系统。使用石墨炉原子吸收检测得出品质因数分析,并基于优化研究提出了静电沉积(ED)工艺的特征。分别获得了As,Se和Sb的30、16和33 pg的绝对检测限(LOD),分别反映了总的产生/收集效率分别为80±5、71±3和62±6%。对于1 ml样品体积,重复测定的精度通常为4%R. S. D.,浓度比LOD高40倍。通过对沿海海水和海洋沉积物认证的参考物质的分析证明了该方法的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号