首页> 外文期刊>Spectrochimica Acta, Part B. Atomic Spectroscopy >Double puise technique for the evaluation of the saturation parameter in single-shot laser induced fluorescence measurements: an application to lead in a flame
【24h】

Double puise technique for the evaluation of the saturation parameter in single-shot laser induced fluorescence measurements: an application to lead in a flame

机译:双脉冲技术在单次激光诱导的荧光测量中评估饱和度参数:在火焰中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

The enlargement of the piobe volume in saturated laser induced fluorescence measurement is a considerable drawback for absolute concentration measurements. For practical purposes, a double pulse technique was developed allowing determination of the saturation parameter, which has a major influence on the probe volume enlargement. The technique is based on the detection of the fluorescence produced by two time-delayed laser pulses of different intensity. The basic theory of the technique is presented,together with the results of an experimental application to Pb in an acetylene/air flame. The implications for absolute concentration measurements are also discussed.
机译:对于绝对浓度测量,饱和激光诱导的荧光测量中探针体积的增大是一个很大的缺点。出于实际目的,开发了一种双脉冲技术,可以确定饱和度参数,这对探头体积的扩大有重大影响。该技术基于对不同强度的两个时间延迟的激光脉冲产生的荧光的检测。介绍了该技术的基本原理,以及在乙炔/空气火焰中对Pb进行实验应用的结果。还讨论了绝对浓度测量的含义。