首页> 外文期刊>Spectrochimica acta, Part A. Molecular and biomolecular spectroscopy >Development of an extractive spectrophotometric method for estimation of uranium in ore leach solutions using 2-ethylhexyl phosphonic acid-mono-2-ethylhexyl ester (PC88A) and tri-n-octyl phosphine oxide (TOPO) mixture as extractant and 2-(5-bromo-2-pyridylozo)-5-diethyl aminophenol (Br-PADAP) as chromophore
【24h】

Development of an extractive spectrophotometric method for estimation of uranium in ore leach solutions using 2-ethylhexyl phosphonic acid-mono-2-ethylhexyl ester (PC88A) and tri-n-octyl phosphine oxide (TOPO) mixture as extractant and 2-(5-bromo-2-pyridylozo)-5-diethyl aminophenol (Br-PADAP) as chromophore

机译:使用2-乙基己基膦酸-单-2-乙基己酯(PC88A)和三正辛基膦氧化物(TOPO)混合物作为萃取剂和2-(5-)的萃取分光光度法估算矿石浸出溶液中的铀溴-2-吡啶基)-5-二乙基氨基苯酚(Br-PADAP)作为生色团

获取原文
获取原文并翻译 | 示例
       

摘要

An extractive spectrophotometric analytical method has been developed for the determination of uranium in ore leach solution. This technique is based on the selective extraction of uranium from multielement system using a synergistic mixture of 2-ethylhexyl phosphonic acid-mono-2-ethylhexyl ester (PC88A) and tri-n-octyl phosphine oxide (TOPO) in cyclohexane and color development from the organic phase aliquot using 2-(5-Bromo-2-pyridylazo)-5-diethyl aminophenol (Br-PADAP) as chromogenic reagent. The absorption maximum (λ _(max)) for UO _2 ~(2+)-Br-PADAP complex in organic phase samples, in 64% (v/v) ethanol containing buffer solution (pH 7.8) and 1,2-cyclohexylenedinitrilotetraacetic acid (CyDTA) complexing agent, has been found to be at 576 nm (molar extinction coefficient, ε: 36,750 ± 240 L mol ~(-1) cm ~(-1)). Effects of various parameters like stability of complex, ethanol volume, ore matrix, interfering ions etc. on the determination of uranium have also been evaluated. Absorbance measurements as a function of time showed that colored complex is stable up to >24 h. Presence of increased amount of ethanol in colored solution suppresses the absorption of a standard UO _2 ~(2+)-Br-PADAP solution. Analyses of synthetic standard as well as ore leach a solution show that for 10 determination relative standard deviation (RSD) is <2%. The accuracy of the developed method has been checked by determining uranium using standard addition method and was found to be accurate with a 98-105% recovery rate. The developed method has been applied for the analysis of a number of uranium samples generated from uranium ore leach solutions and results were compared with standard methods like inductively coupled plasma emission spectrometry (ICPAES). The determined values of uranium concentrations by these methods are within ±2%. This method can be used to determine 2.5-250 μg mL ~(-1) uranium in ore leach solutions with high accuracy and precision.
机译:已经开发了一种萃取分光光度分析方法,用于测定矿石浸出溶液中的铀。该技术基于使用环己烷中的2-乙基己基膦酸-单-2-乙基己酯(PC88A)和三正辛基膦氧化物(TOPO)的协同混合物从多元素系统中选择性萃取铀的技术。用2-(5-溴-2-吡啶基偶氮)-5-二乙基氨基苯酚(Br-PADAP)作显色剂。 UO _2〜(2 +)-Br-PADAP络合物在64%(v / v)含乙醇的缓冲溶液(pH 7.8)和1,2-环己二基三氟四乙酸中的最大吸收(λ_(max))酸(CyDTA)络合剂已发现在576 nm(摩尔消光系数,ε:36,750±240 L mol〜(-1)cm〜(-1))。还评估了各种参数(如配合物的稳定性,乙醇的体积,矿石基质,干扰离子等)对铀测定的影响。吸光度测量值与时间的关系表明,有色配合物在> 24 h内是稳定的。有色溶液中乙醇含量的增加抑制了标准UO _2〜(2 +)-Br-PADAP溶液的吸收。对合成标准液和矿石浸出液的分析表明,对于10次测定,相对标准偏差(RSD)<2%。通过使用标准添加方法测定铀,检查了所开发方法的准确性,发现该方法的准确性为98-105%。该开发的方法已用于分析从铀矿石浸出溶液中产生的许多铀样品,并将结果与​​标准方法(如电感耦合等离子体发射光谱法(ICPAES))进行了比较。通过这些方法确定的铀浓度值在±2%之内。该方法可用于高精度,高精度地测定矿石浸出溶液中2.5-250μgmL〜(-1)铀。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号