OBJECTIVE: To describe a method for the measurement of the accuracy of deep brain stimulation (DBS) electrode placement with the use of image fusion technologies. PATIENTS AND METHODS: Ten consecutive patients suffering from movement disorders underwent DBS electrode placement. Postoperative MR images were fused with the pre-operative stereotactic CT. The placement error in the anteroposterior, lateral and vertical planes was calculated. RESULTS: The anteroposterior mean error +/- SD was 0.61 +/- 0.22 mm (range 0.2-0.9 mm). The lateral mean error +/- SD was 0.65 +/- 0.27 mm (range 0.2-2.2 mm). The vertical mean error +/- SD was 0.82 +/- 0.31 mm (range 0.3-1.6 mm). CONCLUSIONS: This technique provides a simple and precise method for the evaluation of the accuracy of DBS electrode placement.
机译:目的:描述一种使用图像融合技术测量深部脑刺激(DBS)电极放置的准确性的方法。患者与方法:连续十名患有运动障碍的患者接受了DBS电极放置。术后将MR图像与术前立体定向CT融合。计算在前后,侧面和垂直平面中的放置误差。结果:前后平均误差+/- SD为0.61 +/- 0.22毫米(范围0.2-0.9毫米)。横向平均误差+/- SD为0.65 +/- 0.27mm(范围0.2-2.2mm)。垂直平均误差+/- SD为0.82 +/- 0.31毫米(范围0.3-1.6毫米)。结论:该技术提供了一种简单而精确的方法来评估DBS电极放置的准确性。