首页> 外文期刊>Spine >Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the Spinal Deformity Study Group's AIS Radiographic Measurement Manual.
【24h】

Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the Spinal Deformity Study Group's AIS Radiographic Measurement Manual.

机译:《脊椎畸形研究组的AIS射线照相测量手册》中射线照相参数的观察者内部再现性和观察者之间可靠性。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY DESIGN: Retrospective cross-sectional assessment of the reproducibility and reliability of radiographic parameters. OBJECTIVE: To measure the intra-examiner and interexaminer reproducibility and reliability of salient radiographic features. SUMMARY OF BACKGROUND DATA: The management and treatment of adolescent idiopathic scoliosis (AIS) depends on accurate and reproducible radiographic measurements of the deformity. METHODS: Ten sets of radiographs were randomly selected from a sample of patients with AIS, with initial curves between 20 degrees and 45 degrees. Fourteen measures of the deformity were measured from posteroanterior and lateral radiographs by 2 examiners, and were repeated 5 times at intervals of 3-5 days. Intra-examiner and interexaminer differences were examined. The parameters include measures of curve size, spinal imbalance, sagittal kyphosis and alignment, maximum apical vertebral rotation, T1 tilt, spondylolysis/spondylolisthesis, and skeletal age. RESULTS: Intra-examiner reproducibility was generally excellent for parameters measured from the posteroanterior radiographs but only fair to good for parameters from the lateral radiographs, in which some landmarks were not clearly visible. Of the 13 parameters observed, 7 had excellent interobserver reliability. CONCLUSIONS: The measurements from the lateral radiograph were less reproducible and reliable and, thus, may not add value to the assessment of AIS. Taking additional measures encourages a systematic and comprehensive assessment of spinal radiographs.
机译:研究设计:对射线照相参数的可重复性和可靠性的回顾性横断面评估。目的:测量检查者和检查者之间的可重复性和显着放射学特征的可靠性。背景资料摘要:青少年特发性脊柱侧凸(AIS)的管理和治疗取决于畸形的准确且可重复的X线照片。方法:从AIS患者的样本中随机选择十组X射线照片,其初始曲线在20度到45度之间。由两名检查者从后前和外侧X射线照片测量了14个畸形测量值,并在3-5天的间隔内重复了5次。检查了检查者内和检查者间的差异。这些参数包括曲线大小,脊柱不平衡,矢状后凸和对齐,最大椎体顶旋度,T1倾斜度,脊椎裂/脊柱滑脱和骨骼年龄的量度。结果:检查者内部的可重复性对于从后前X线片测量的参数通常是极好的,但是对于侧面X线片的参数来说是相当好的,因为侧面X线片中的一些标志性图像并不清晰可见。在观察到的13个参数中,有7个具有极好的观察者间可靠性。结论:侧位片的测量结果重复性和可靠性较差,因此可能无法为AIS的评估增加价值。采取额外措施可鼓励对脊柱X光片进行系统且全面的评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号