STUDY DESIGN: Use of magnetic resonance imaging (MRI) with Constructive Interference in Steady State (CISS) sequence and isometric voxels to demonstrate the anatomic variations of vertebral artery in C2 vertebra. OBJECTIVES: To determine the transarticular screw trajectory on CISS MRI and to identify patients with anatomic variations of vertebral artery in C2 vertebra. SUMMARY OF BACKGROUND DATA: Atlantoaxial transarticular screw fixation has been reported to be biomechanically superior to other posterior techniques for atlantoaxial arthrodesis. Vertebral artery injury can be associated with catastrophic sequelae. Anatomic variation of vertebral artery is well recognized and computed tomography scan is the traditional preoperative assessment. However, no report has evaluated the use of MRI in preoperative assessment for the screw trajectories and the anatomic variation of vertebral artery. METHODS: The 3-dimensional (3D) CISS MRI with isometric voxels was performed in 30 local Chinese patients. The 3D reconstruction images were created to determine the proposed screw trajectories and their relationship with the vertebral arteries. RESULTS: In 12 patients (40%), the vertebral arteries were lying within the screw trajectories prohibiting transarticular screw fixation on at least one side. Bilateral variations with high risk of vertebral artery injuries were found in 6 patients. The remaining 6 patients had unilateral variations prohibiting the insertion of transarticular screws on one side. CONCLUSION: The 3D CISS MRI with isometric voxels is a safe and simple imaging technique to outline the vertebral arteries in C2. Reconstruction images are easily created and undistorted. It is one of the useful imaging in preoperative planning of transarticular screw fixation and determination of anatomy of vertebral artery.
机译:研究设计:运用磁共振成像(MRI)和稳定状态(CISS)序列中的建设性干扰以及等距体素来证明C2椎骨中椎动脉的解剖学变化。目的:在CISS MRI上确定经关节螺钉的轨迹,并确定C2椎骨椎动脉解剖变异的患者。背景数据概述:据报道,寰枢椎经关节螺钉固定在生物力学上优于其他后路技术。椎动脉损伤可伴有灾难性后遗症。椎动脉的解剖学变化是公认的,计算机断层扫描是传统的术前评估。但是,尚无报道评估MRI在术前评估螺钉轨迹和椎动脉解剖变异中的应用。方法:对30位中国本地患者进行了三维等距三维三维CISS MRI检查。创建3D重建图像以确定拟议的螺钉轨迹及其与椎动脉的关系。结果:在12例患者(占40%)中,椎动脉位于螺钉轨道内,禁止在至少一侧固定经关节螺钉。在6例患者中发现了具有高椎动脉损伤风险的双边变异。其余6例患者有单侧变异,禁止在一侧插入经关节螺钉。结论:带有等距体素的3D CISS MRI是概述C2椎动脉轮廓的一种安全,简单的成像技术。重建图像易于创建且不会变形。它是术前计划经关节螺钉固定和确定椎动脉解剖结构的有用影像之一。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号