首页> 外文期刊>Spine >Biomechanical analysis of the range of motion after placement of a two-level cervical ProDisc-C versus hybrid construct.
【24h】

Biomechanical analysis of the range of motion after placement of a two-level cervical ProDisc-C versus hybrid construct.

机译:放置两级宫颈ProDisc-C与混合结构后的运动范围的生物力学分析。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY DESIGN: The study design was that of an in vitro human cadaveric biomechanical analysis. OBJECTIVES: The objective of this study was the biomechanical analysis of the range of motion (ROM) of a 2-level intact spine control versus total, then operative- and adjacent-segment ROM after (1) 2-level ProDisc-C placement (PP), (2) anterior cervical discectomy and fusions (ACDFs), and (3) hybrid constructs of both. Follower load and multidirectional testing were performed in each instance. SUMMARY OF BACKGROUND DATA: With in vivo cervical arthroplasties gaining in popularity, limited biomechanical data are available, which highlight changes in the adjacent-level biomechanics after multilevel procedures. METHODS: Biomechanical testing for ROM was performed using 7 cadaveric C4-T1 spine specimens. Moments up to 2 Nm with a 100 N follower load were applied in flexion/extension (F/E), right and left lateral bending (LB), and right and left axial rotation (AR). Specimens were tested in the intact state and then with a combination of ProDisc-C arthroplasty and ACDF at C5-C6 and C6-C7. RESULTS: In the 2-level PP group, the increase in ROM in F/E, LB, and AR of C4-T1 occurs due to an increased ROM at the operative level. The ROM of the level adjacent to the operative levels showed no significant change, except at C4-C5 in LB. For the latter level, the ROM of C4-C5 in each direction showed increases for each parameter. In the 2-level fusion C5-C6 and C6-C7 fusion (FF) group, the ROM in F/E, LB, and AR of C4-T1 was decreased because of a decrease in ROM primarily at the fused levels, and the ROM of adjacent levels was increased. In the ProDisc-C/Fusion (PF) and Fusion/ProDisc-C (FP) groups undergoing placements of a 1-level ProDisc-C/1-level fusion with cage and plate, both groups showed no significant ROM change of C4-T1 when compared with the control and no significant change at adjacent levels, with the exception of C4-C5 in LB. CONCLUSION: (1) Two-level ACDFs decrease whereas 2-level PPs increase the entire C4-T1 ROM. (2) ACDF/ProDisc-C hybrid operations do not alter the C4-T1 ROM. (3) For the ACDF/ProDisc-C hybrid operative groups, the combined ROM of the operative levels showed no significant difference when compared with that of the intact spine. (4) Regarding adjacent-level ROM, a 2-level ACDF increases ROM, but 2-level ProDisc-C and hybrid ACDF/PPs do not show significant change except for LB at C4-C5. (5) When the segmental distribution of C4-T1 ROM is plotted as the percentage of total motion, it demonstrates that for PF and FP groups, the combined ROM of the C5-C6 and C6-C7 operative levels are similar to that of the intact spine in EF and LB. For the PP group, the combined ROM of the operative levels increased, whereas the combined ROM for the FF group is decreased. The decrease or increase of the adjacent C4-C5 or C7-T1 level ROM compensates for the operative levels.
机译:研究设计:研究设计是体外人体尸体生物力学分析的设计。目的:本研究的目的是对(1)2层ProDisc-C放置后2层完整脊柱对照相对于总,然后是手术和邻近段ROM的运动范围(ROM)进行生物力学分析。 PP),(2)前颈椎间盘摘除术和融合术(ACDF),以及(3)两者的混合构建体。在每种情况下都执行了跟踪器负载和多方向测试。背景技术概述:随着体内颈椎置换术的流行,有限的生物力学数据是可用的,这突出了多级手术后相邻级生物力学的变化。方法:使用7具尸体C4-T1脊柱标本对ROM进行生物力学测试。在屈曲/伸展(F / E),左右横向弯曲(LB)和左右轴向旋转(AR)时施加高达2 Nm的力矩,并具有100 N的从动载荷。样品在完整状态下进行测试,然后在C5-C6和C6-C7处结合ProDisc-C关节置换术和ACDF。结果:在2级PP组中,C4-T1的F / E,LB和AR中ROM的增加是由于手术级ROM的增加。接近手术水平的ROM显示无明显变化,除了LB中的C4-C5。对于后者,对于每个参数,C4-C5的ROM在每个方向上均显示增加。在2级融合C5-C6和C6-C7融合(FF)组中,C4-T1的F / E,LB和AR中的ROM减少了,因为ROM的减少主要是在融合级,并且相邻级别的ROM增加了。在ProDisc-C /融合(PF)和Fusion / ProDisc-C(FP)组中进行的1级ProDisc-C / 1级融合(带有笼板)的放置中,两组均未显示C4的显着ROM变化与对照相比,T1且在相邻水平上无显着变化,但LB中的C4-C5除外。结论:(1)二级ACDF减少,而二级PP则增加整个C4-T1 ROM。 (2)ACDF / ProDisc-C混合操作不会更改C4-T1 ROM。 (3)对于ACDF / ProDisc-C混合手术组,与完整脊柱相比,手术水平的组合ROM没有显着差异。 (4)关于相邻级别的ROM,2级ACDF增加了ROM,但是2级ProDisc-C和混合ACDF / PP除了C4-C5处的LB以外,没有显示出显着变化。 (5)当将C4-T1 ROM的分段分布绘制为总运动的百分比时,表明对于PF和FP组,C5-C6和C6-C7操作级别的组合ROM与C5-T6 ROM的组合ROM相似。 EF和LB中完整的脊柱。对于PP组,手术水平的合并ROM增加,而FF组的合并ROM降低。相邻C4-C5或C7-T1级别ROM的减少或增加补偿了操作级别。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号