Combined measurement of nerve root blood flow and electrophysiological values: intraoperative straight-leg-raising test for lumbar disc herniation.

机译:结合测量神经根血流量和电生理值:术中直腿抬高试验用于腰椎间盘突出症。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY DESIGN: A total of 15 patients with lumbar disc herniation at the L5-S1 disc level who underwent microendoscopic discectomy were examined. The nerve root blood flow and electrophysiological values were measured during an intraoperative straight-leg-raising (SLR) test. OBJECTIVE: To investigate the relationships between nerve root blood flow changes and the electrophysiological values during an intraoperative SLR test. SUMMARY OF THE BACKGROUND DATA: It is unknown how the electrophysiological values are affected by nerve root blood flow changes during an SLR test. METHODS: We measured S1 nerve root blood flow and electrophysiologically evaluated the nerve root using the compound muscle action potentials (CMAPs) from the gastrocnemius muscle after S1 nerve root stimulation during an intraoperative SLR test. Subsequently, we analyzed the relationships between the nerve root blood flow changes and the electrophysiological values. RESULTS: Before discectomy, there were sharp decreases in the nerve root blood flow after 1 and 3 minutes of the SLR test (P < 0.001), and the amplitudes of the CMAPs deteriorated significantly (P < 0.001). Significant correlations were found between the decrease ratio for the nerve root blood flow during the SLR test and the deterioration ratio for the amplitude of the CMAPs. After discectomy, the blood flow increased significantly (P = 0.001). When the SLR test was performed again, the blood flow showed no significant decreases. The average amplitudes of the CMAPs were significantly ameliorated (P < 0.01). When the SLR test was performed again, no significant differences were found for the average amplitudes after 1 and 3 minutes of the test. CONCLUSION: Significant correlations were found between the decrease ratio for the nerve root blood flow and the deterioration ratio for the amplitude of the CMAPs. The present results demonstrate that temporary ischemic changes in the nerve root cause transient conduction disturbances.
机译:研究设计:总共15例腰椎间盘突出症的L5-S1椎间盘突出症患者接受了微内镜下椎间盘切除术。在术中直腿抬高(SLR)测试期间测量了神经根的血流量和电生理值。目的:探讨术中单反试验中神经根血流变化与电生理值之间的关系。背景数据概述:在SLR测试期间,神经根血流变化如何影响电生理值尚不清楚。方法:我们在术中SLR测试期间,在S1神经根刺激后,使用腓肠肌的复合肌肉动作电位(CMAP)测量了S1神经根的血流,并对神经根进行了电生理学评估。随后,我们分析了神经根血流变化与电生理值之间的关系。结果:在椎间盘切除术之前,SLR试验1分钟和3分钟后神经根血流量急剧减少(P <0.001),并且CMAP的幅度明显下降(P <0.001)。发现在SLR测试期间神经根血流的减少率与CMAP幅度的恶化率之间存在显着的相关性。椎间盘切除术后,血流量显着增加(P = 0.001)。再次执行SLR测试时,血流没有明显减少。 CMAP的平均幅度得到明显改善(P <0.01)。当再次执行SLR测试时,在测试1分钟和3分钟后,平均振幅没有发现明显差异。结论:神经根血流减少率与CMAP幅度降低率之间存在显着相关性。目前的结果表明,神经根的暂时性缺血变化会引起短暂的传导障碍。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号