首页> 外文期刊>Spine >Trunk muscle endurance measurement. Isometric contrasted to isokinetic testing in normal subjects.
【24h】

Trunk muscle endurance measurement. Isometric contrasted to isokinetic testing in normal subjects.

机译:躯干肌肉耐力测量。在正常受试者中,等距与等速测试相反。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY DESIGN. This cohort study examined a sample (n = 152) of subjects tested for isokinetic lumbar strength and endurance, using novel endurance measures. OBJECTIVES. To validate a new lumbar sagittal isokinetic endurance testing protocol comparing reliability in a normal subject cohort with strength test reliability to include presentation of a gender-specific normative database, and then correlating the results to a Sorenson isometric endurance protocol. SUMMARY OF BACKGROUND DATA. The isometric Sorenson test has been virtually the only validated clinical tool for lumbar extensor trunk muscle endurance testing, using an exercise chair and permitting the subject to maintain the trunk horizontal against gravity for a single timed contraction. Alternative isokinetic sagittal lumbar performance measurement methodology has been developed recently to measure trunk muscle endurance by determining declining work performance on repeated, reciprocal dynamic contractions. METHOD. We compared protocols, performance measures, normative data, and reliability for the static isometric Sorenson test to three different isokinetic endurance measurements: the endurance ratio, final fatigue ratio, and recovery ratio. Subjects were tested on a sagittal Cybex TEF (Lumex, Inc., Ronkonkoma, NY) unit for a strength trial followed by an endurance trial. Subgroups also performed reliability and isometric endurance protocols. RESULTS. We found an extremely low test-retest correlation for the isometric Sorenson trunk extension test. All test-retest correlations for the corresponding isokinetic endurance measures were significant and markedly higher. Extensor muscle performance declined more substantially on all endurance measures than flexors and showed more variability. In contrast, trunk strength measures were more reliable and less variable than corresponding endurance measures. Moreover, correlations between the isometric Sorenson test and the isokinetic endurance measures were all negative; i.e., increases in Sorenson time are moderately correlated to greater decline in work performance. CONCLUSIONS. Reliability of the Sorenson isometric endurance test is unacceptably low, showing negative correlations to all isokinetic endurance tests for lumbar extensors. Isokinetic strength and endurance tests are far more reliable than isometric tests, with normative data showing more consistent results from men than women. Both genders display more substantial fatigue (and greater variability) in extensor endurance compared with flexor testing. Endurance measures are identified as human performance cognitive constructs, and reasons for greater variability than usually shown by trunk strength measurements are discussed.
机译:学习规划。这项队列研究使用新颖的耐力测量方法检查了样本(n = 152)的受试者的等速腰椎力量和耐力。目标为了验证新的腰椎矢状等速耐力测试协议,将正常受试者队列中的可靠性与强度测试的可靠性进行比较,以包括特定性别的规范数据库的呈现,然后将结果与Sorenson等距耐力协议相关联。背景数据摘要。等距的Sorenson测试实际上是腰椎伸肌躯干耐力测试的唯一经过验证的临床工具,它使用运动椅并允许受试者在单次收缩时保持躯干抵抗重力水平。最近已经开发出替代的等速矢状腰椎性能测量方法,以通过确定重复的,往复的动态收缩的工作性能下降来测量躯干肌肉的耐力。方法。我们将静态等距Sorenson测试的协议,性能指标,标准数据和可靠性与三种不同的等速耐力测量值进行了比较:耐久比,最终疲劳比和恢复比。受试者在矢状Cybex TEF(纽约州朗肯科马市的Lumex公司)上进行了力量测试,然后进行了耐力测试。亚组还执行可靠性和等距耐力协议。结果。我们发现等距Sorenson躯干延伸测试的重测相关性极低。相应的等速耐力测试的所有重测相关性均显着且明显更高。在所有耐力​​指标上,伸肌的表现均比屈指更为明显,并且表现出更大的变异性。相比之下,躯干力量指标比相应的耐力指标更可靠且变化较小。而且,等距Sorenson检验与等速耐力测量值之间的相关性均为负。即Sorenson时间的增加与工作绩效的更大下降有一定的关联。结论。 Sorenson等距耐力测试的可靠性低得令人无法接受,显示与腰部伸肌的所有等速耐力测试呈负相关。等速力量和耐力测试远比等轴测验可靠,规范数据显示,男性比女性更一致的结果。与屈肌测试相比,这两种性别的伸肌耐力都表现出更大程度的疲劳(和更大的变异性)。耐力措施被识别为人类表现的认知构造,并讨论了比躯干力量测量结果通常显示的更大变异性的原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号