Microclimate evaluation of a new design of insect-proof screens in a Mediterranean greenhouse.

机译:地中海温室防虫网新型设计的微气候评估。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This work studies natural ventilation in a Mediterranean greenhouse, comparing a new experimental screen of 13x30 threads cm-2 (porosity 39.0%) with a commercial control screen of 10x20 threads cm-2 (porosity 33.5%). In addition, both screens were tested in a wind tunnel to determine the discharge coefficients Cd of the greenhouse side and roof vents, which proved to be 0.16 for the commercial control screen and 0.18 for the experimental screen at both vents. These values represent a theoretical increase of 11% (Cd phi -10x20/Cd phi -13x30=0.89) in the natural ventilation capacity of the greenhouse when the experimental screen is used. The greenhouse was divided into two separate sections allowing us to analyze natural ventilation in both sectors simultaneously. Air velocity was measured in the lateral and roof vents with two 3D and six 2D sonic anemometers. Using the commercial control screen there was an average reduction of 16% in ventilation rate, and an average increase of 0.5 degrees C in the average indoor air temperature, compared to the experimental screen. In addition, the ventilation efficiency eta T was higher with the experimental screen (mean value of 0.9) than with the control (mean value 0.6). We have designed an experimental insect-proof screen (13x30 threads cm-2) with smaller thread diameter, higher thread density, smaller pore size and higher porosity than are used in most commercial meshes. All of these factors promote natural ventilation and improve the greenhouse microclimate.
机译:这项工作研究了地中海温室中的自然通风,将13x30螺纹cm -2 (孔隙度39.0%)的新实验筛网和10x20螺纹cm -2 (孔隙度33.5%)。另外,在风洞中对两个滤网进行了测试,以确定温室侧和屋顶通风口的排放系数Cd,对于商用控制滤网,两个通风口的实验滤网的排放系数Cd均为0.16。当实验筛选时,这些值表示温室的自然通风量在理论上增加了11%(C phi -10x20 / C d phi -13x30 = 0.89)。用来。温室分为两个独立的部分,使我们可以同时分析两个部门的自然通风。使用两个3D和六个2D声波风速计在侧面和屋顶通风口中测量风速。与实验屏相比,使用商用控制屏时,通风率平均降低了16%,平均室内空气温度平均提高了0.5摄氏度。另外,实验筛(平均值为0.9)的通风效率eta T高于对照组(平均值为0.6)。我们设计了一个实验性的防虫网(13x30线cm -2 ),与大多数商业网眼相比,该线具有较小的线径,较高的线密度,较小的孔径和较高的孔隙率。所有这些因素都促进了自然通风并改善了温室的小气候。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号