首页> 外文期刊>ORL: Journal for oto-rhino-laryngology and its borderlands >Clinical value of the high expression of corticosteroid receptor-beta mRNA in the nasal mucosa of steroid-resistant patients with allergic rhinitis
【24h】

Clinical value of the high expression of corticosteroid receptor-beta mRNA in the nasal mucosa of steroid-resistant patients with allergic rhinitis

机译:激素抵抗性变应性鼻炎患者鼻黏膜中糖皮质激素受体βmRNA高表达的临床价值

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: This study investigated clinical values of corticosteroid (CS) receptor α and β in the nasal mucosa of patients with allergic rhinitis (AR) by determining CS receptor α and β mRNA expression following steroid treatment. Procedures: Among 120 outpatients, 65 had persistent AR, including 36 being sensitive to steroid treatment (steroid-sensitive group) and 29 being resistant to steroid treatment (steroid-resistant group). In addition, 30 patients with deflection of the nasal septum alone, which was corrected by surgery, were recruited as controls. Fluorescent quantitative reverse transcription-PCR was used to quantify CS receptor α and β mRNA expression in the nasal mucosa of patients. Results: Results showed that CS receptor β mRNA expression in the nasal mucosa was significantly higher in the steroid-resistant group [(5.62 ± 1.28) × 102 copies/μg] compared with the steroid-sensitive [(4.62 ± 0.48) × 102 copies/μg, t =-6.67, p < 0.01] and control [(5.32 ± 0.55) × 102 copies/μg, t =-8.29, p < 0.01] groups. There were significant differences in the mRNA expression ratio of CS receptor α to β between the steroid-sensitive (658.32 ± 65.16) and steroid-resistant (525.70 ± 68.10) groups (t = 10.16, p < 0.01). Conclusion: A high level of CS receptor β mRNA but a low level of CS receptor α mRNA expression in patients with steroid-resistant AR indicates steroid resistance. CS receptor β plays a role in evaluating the effects of steroid therapy for AR.
机译:目的:本研究通过确定类固醇激素治疗后CS受体α和βmRNA的表达,研究皮质类固醇(CS)受体α和β在过敏性鼻炎(AR)患者鼻黏膜中的临床价值。程序:在120名门诊患者中,65例持续性AR,其中36例对类固醇治疗敏感(类固醇敏感组)和29例对类固醇治疗耐药(类固醇耐药组)。另外,招募了30名仅通过手术矫正的鼻中隔偏曲的患者作为对照。荧光定量逆转录PCR用于定量检测患者鼻黏膜中CS受体α和βmRNA的表达。结果:结果表明,类固醇抵抗组鼻粘膜中CS受体βmRNA的表达[5.62±1.28)×102个拷贝/μg显着高于对类固醇敏感的组((4.62±0.48)×102个拷贝。 /μg,t = -6.67,p <0.01]和对照组[(5.32±0.55)×102拷贝/μg,t = -8.29,p <0.01]组。类固醇敏感性组(658.32±65.16)和类固醇抵抗组(525.70±68.10)之间,CS受体α与β的mRNA表达比率存在显着差异(t = 10.16,p <0.01)。结论:类固醇抵抗性AR患者CS受体βmRNA水平高而CS受体αmRNA水平低表明类固醇抵抗。 CS受体β在评估类固醇治疗AR的作用中发挥作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号