Electrical performance results from physical stress testing of commercial PV modules to the IEC 61215 test sequence

机译:电气性能由商用光伏模块的物理应力测试到IEC 61215测试顺序得出

获取原文
获取原文并翻译 | 示例
           

摘要

This paper presents statistical analysis of the behaviour of the electrical performance of commercial crystalline silicon photovoltaic (PV) modules tested in the Solar Test Installation of the European Commission's joint Research Centre from 1990 up to 2006 to the IEC Standard 61215 and its direct predecessor CEC Specification 503. A strong correlation between different test results was not observed, indicating that the standard is a set of different, generally independent stress factors. The results confirm the appropriateness of the testing scheme to reveal different module design problems related rather to the production quality control than material weakness in commercial PV modules. (C) 2008 Elsevier B.V. All rights reserved.
机译:本文介绍了统计晶体分析的商业晶体硅光伏(PV)组件的电性能的行为,该组件在1990年至2006年间由欧盟委员会联合研究中心进行的太阳能测试安装中一直按照IEC标准61215及其直接的前CEC规范进行测试503.未观察到不同测试结果之间的强相关性,表明该标准是一组不同的,通常独立的应力因子。结果证实了测试方案的适当性,以揭示与光伏产品质量控制有关的,与产品质量控制有关的不同组件设计问题,而不是商用光伏组件的材料缺陷。 (C)2008 Elsevier B.V.保留所有权利。