...
首页> 外文期刊>Skeletal radiology >Minimum joint space width (mJSW) of patellofemoral joint on standing skyline radiographs: Test-retest reproducibility and comparison with quantitative magnetic resonance imaging (qMRI)
【24h】

Minimum joint space width (mJSW) of patellofemoral joint on standing skyline radiographs: Test-retest reproducibility and comparison with quantitative magnetic resonance imaging (qMRI)

机译:站立式X线片上pa股关节的最小关节间隙宽度(mJSW):重测重现性并与定量磁共振成像(qMRI)比较

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objective: To assess the intraobserver, interobserver, and test-retest reproducibility of minimum joint space width (mJSW) measurement of medial and lateral patellofemoral joints on standing skyline radiographs and to compare the mJSW of the patellofemoral joint to the mean cartilage thickness calculated by quantitative magnetic resonance imaging (qMRI). Materials and methods: A couple of standing skyline radiographs of the patellofemoral joints and MRI of 55 knees of 28 volunteers (18 females, ten males, mean age, 48.5 ± 16.2 years) were obtained on the same day. The mJSW of the patellofemoral joint was manually measured and Kellgren and Lawrence grade (KLG) was independently assessed by two observers. The mJSW was compared to the mean cartilage thickness of patellofemoral joint calculated by qMRI. Results: mJSW of the medial and lateral patellofemoral joint showed an excellent intraobserver agreement (interclass correlation (ICC) = 0.94 and 0.96), interobserver agreement (ICC = 0.90 and 0.95) and test-retest agreement (ICC = 0.92 and 0.96). The mJSW measured on radiographs was correlated to mean cartilage thickness calculated by qMRI (r = 0.71, p < 0.0001 for the medial PFJ and r = 0.81, p < 0.0001 for the lateral PFJ). However, there was a lack of concordance between radiographs and qMRI for extreme values of joint width and KLG. Radiographs yielded higher joint space measures than qMRI in knees with a normal joint space, while qMRI yielded higher joint space measures than radiographs in knees with joint space narrowing and higher KLG. Conclusions: Standing skyline radiographs are a reproducible tool for measuring the mJSW of the patellofemoral joint. The mJSW of the patellofemoral joint on radiographs are correlated with, but not concordant with, qMRI measurements.
机译:目的:评估站立式X线片上内侧和外侧of股关节的最小关节间隙宽度(mJSW)测量值的观察者内,观察者间以及重测的可重复性,并将compare股关节的mJSW与通过定量计算得出的平均软骨厚度进行比较磁共振成像(qMRI)。材料和方法:当天获得了28例志愿者(18名女性,10名男性,平均年龄为48.5±16.2岁)的of股关节的站立式X线照片和55膝的MRI。手动测量the股关节的mJSW,并由两名观察员独立评估Kellgren和Lawrence评分(KLG)。将mJSW与qMRI计算得出的tell股关节平均软骨厚度进行比较。结果:内侧和外侧pa股关节的mJSW显示了极好的观察者内一致性(类间相关性(ICC)= 0.94和0.96),观察者间一致性(ICC = 0.90和0.95)和重测一致性(ICC = 0.92和0.96)。放射线照片上测得的mJSW与qMRI计算得出的平均软骨厚度相关(内侧PFJ的r = 0.71,p <0.0001,外侧PFJ的r = 0.81,p <0.0001)。但是,对于关节宽度和KLG的极值,X线照片和qMRI之间缺乏一致性。在关节空间正常的膝关节中,X线片比qMRI可获得更高的关节间隙,而在关节间隙变窄且KLG较高的膝盖中,qMRI产生的关节间隙比X射线更高。结论:站立式射线照相是测量measuring股关节mJSW的可复制工具。 X线片上of股关节的mJSW与qMRI测量值相关,但不一致。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号