Radial artery catheterization is a common procedure performed in the cardiac catheterization laboratory. Transradial accesssing is becoming an increasingly widespread choice because of its lower complications compared with the transfemoral approach. Although complications related to this procedure are well established, troubles associated with the guide wire are rare. We present the first reported case of a percutaneous rescue of a wire during radial sheath insertion using the balloon entrapment technique to retrieve it without surgery.
机译:ial动脉导管插入术是在心脏导管插入术实验室中执行的常见程序。经radi动脉入路由于与经股动脉入路相比并发症少,因此正成为一种越来越普遍的选择。尽管已经很好地确定了与该手术相关的并发症,但是与导丝相关的麻烦很少。我们介绍了第一例报道的在径向鞘管插入过程中使用球囊捕获技术经皮经皮抢救电线的情况,无需手术即可将其取回。