摘要

Stent delivery failure to the distal lesion was still encountered even after the introduction of mother-child technique using a 5. F or 4. F child catheter. A 5. F inner catheter with a length of 112. cm, and a 4. F inner catheter with a length of 122. cm enabled a novel mother-child-grandchild technique. In in vitro experiments, not only was backup support increased, but superior trackability could also be obtained with the mother-child-grandchild technique, over the mother-child technique. We describe the clinical data using this novel mother-child-grandchild technique to deliver a stent to the severely bended and/or calcified distal lesion.
机译:即使在使用5. F或4. F儿童导管引入母子技术后,仍然会遇到向远端病变的支架递送失败。长度为112. cm的5. F内导管和长度为122. cm的4. F内导管使新的母子孙技术成为可能。在体外实验中,不仅增加了后备支持,而且使用母子孙技术比母子技术还可以获得更好的可跟踪性。我们描述了使用这种新颖的母子技术来将支架递送至严重弯曲和/或钙化的远端病变的临床数据。