首页> 外文期刊>Separation and Purification Technology >Fluoride removal from drinking water by electrocoagulation in a continuous filter press reactor coupled to a flocculator and clarifier
【24h】

Fluoride removal from drinking water by electrocoagulation in a continuous filter press reactor coupled to a flocculator and clarifier

机译:在与絮凝器和澄清器相连的连续压滤反应器中通过电凝从饮用水中去除氟化物

获取原文
获取原文并翻译 | 示例
       

摘要

This investigation is about fluoride removal from synthetic drinking water (10 mg L~(-1)F~ in 0.5 gL~(-1)Na2SO4 and 1.5 mg L~(-1)ClO~- at pH 7.7 and conductivity 410 μS cm~(-1)), by electrocoagulation (EC) using aluminum as the sacrificial anode in a continuous filter press reactor coupled to a flocculator and clarifier (sludge settler). The influence of current density (j) and linear flow velocity in the EC reactor (μ_r) on the fluoride removal efficiency was analyzed. The EC tests that satisfy the WHO norm for fluoride (C_F< 1.5mgL~(-1)) were obtained at 0.91 < u_r< 1.82 cm s~(-1)and 5
机译:这项研究是关于在pH 7.7和电导率410μScm下从合成饮用水(0.5 gL〜(-1)Na2SO4和1.5 mg L〜(-1)ClO〜-中的10 mg L〜(-1)F〜 〜(-1)),在与絮凝器和澄清器(污泥沉降器)相连的连续压滤反应器中,使用铝作为牺牲阳极,通过电凝(EC)。分析了电抗器中电流密度(j)和线性流速(μ_r)对除氟效率的影响。在0.91