首页> 外文期刊>Separation and Purification Technology >Desalination by vacuum membrane distillation: semsitivity analysis
【24h】

Desalination by vacuum membrane distillation: semsitivity analysis

机译:真空膜蒸馏法脱盐:灵敏度分析

获取原文
获取原文并翻译 | 示例

摘要

In order to enhance the performance of the vacuum embrane distillation process in desalination, i.e.to get more flux, it is necessary to study the effect of operating parameters on the yield of distillate water, Simple techniques including the normalized dimensionless sensitivity factor and temperature polarization coefficient as well as the solution of the transport models were used for this purpose. The senstivity of the mass flux to the process operating parameters including downstream pressure, feed temperature feed flow rate, and mimbrane permeability were investigated. The mass flux of distillate water was more sensitive to the vacuum pressure at low feed temperature levels than at the high ones. Since lowering the temperature polarization coefficient is essential to enhance the process performance considerable efforts should be directed toward maximizing the heat transfer coefficient through better module design. The predictions of the normalized dimensionless sensitivity analysis were in agreement with the results obtained from solving the transport model of the process.
机译:为了提高真空支链蒸馏工艺在脱盐中的性能,即获得更多的通量,有必要研究操作参数对蒸馏水产率的影响。归一化无量纲灵敏度因子和温度极化系数的简单技术以及运输模型的解决方案都用于此目的。研究了质量通量对工艺操作参数(包括下游压力,进料温度,进料流速和膜渗透性)的敏感性。在低进料温度下,馏出水的质量通量比在高进料温度下对真空压力更敏感。由于降低温度极化系数对于提高工艺性能至关重要,因此应该通过更好的模块设计来努力使传热系数最大化。归一化无量纲敏感性分析的预测与解决过程的运输模型所获得的结果一致。