BACKGROUND: Biochemical quality control (QC) data have been reported to be autocorrelated. Serial correlation may increase the rate of false alarms if the traditional exponentially weighted moving average (EWMA) control chart to monitoring the process mean is used. False alarms are the focus of this paper, where an alarm is defined as the occurrence of a QC value outside the three standard deviation control limits. METHODS: Daily QC measurements of common biochemical (Vitros 500) and hematological (SF-3000 and Behring Coagulation Timer (BCT)) quantities were recorded during several months while methods and analyzers showed no signs of malfunctioning. The time series were examined for autocorrelation and the performance of the EWMAST chart was compared with that of the EWMA chart when autocorrelation was present. RESULTS: Many of the time series showed significant signs of autocorrelation. Using the EWMA chart to monitor the process mean, false alarms were noted for positively autocorrelated time series, while this was seldom the case when the EWMAST chart was used. For some quantities, the EWMAST chart gave alarms. However, when the process autocorrelation and therefore the limits of the control chart were updated, the alarms given by the EWMAST chart were reduced or disappeared. In some cases the mean level changed over time, which is expected due to calibrations. This problem will be the topic of a subsequent paper. CONCLUSIONS: Positive autocorrelation may be present in QC data. In this case the EWMAST chart should be used in place of the EWMA chart.
机译:背景:生化质量控制(QC)数据据报道是自相关的。如果使用传统的指数加权移动平均值(EWMA)控制图来监视过程平均值,则串行相关性可能会增加错误警报的发生率。虚假警报是本文的重点,其中警报定义为出现在三个标准偏差控制范围之外的QC值。方法:几个月内记录了日常生化指标(Vitros 500)和血液学指标(SF-3000和贝林凝血定时器(BCT))的质量控制(QC)量,而方法和分析仪均未出现故障迹象。检查时间序列的自相关,并在存在自相关时将EWMAST图表的性能与EWMA图表的性能进行比较。结果:许多时间序列显示出明显的自相关迹象。使用EWMA图表监视过程平均值,会发现与正相关的时间序列存在误报,而使用EWMAST图表时很少出现这种情况。对于某些数量,EWMAST图表发出警报。但是,当过程自相关以及控制图的限制更新时,EWMAST图给出的警报将减少或消失。在某些情况下,平均水平会随时间而变化,这是校准所期望的。这个问题将成为后续论文的主题。结论:QC数据中可能存在正自相关。在这种情况下,应使用EWMAST图表代替EWMA图表。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号