首页> 外文期刊>Sadhana: Academy Proceedings in Engineering Science >Simplified loss analysis and comparison of full-bridge, full-range-ZVS DC-DC converters
【24h】

Simplified loss analysis and comparison of full-bridge, full-range-ZVS DC-DC converters

机译:全桥,全范围ZVS DC-DC转换器的简化损耗分析和比较

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The loss of zero-voltage-switching (ZVS) of active switches has been a serious limitation of full-bridge (FBZVS) converters. Many techniques have been proposed in the past to extend the range of ZVS operation over the wider and also the full range of operation. However, in these techniques ZVS is achieved at the expense of additional conduction loss in active switches and losses in the auxiliary components. In this paper, the analysis for the additional losses in various full-range FBZVS DC-DC converters and their comparative evaluation is reported. Closed form expressions are derived for average value of device currents and losses. The loss curves for various topologies are plotted and compared. The analytical results are found to be consistent with the experimental efficiency tests performed on 500 W, 100 kHz prototype. It is concluded that a recently proposed new topology has the least penalty of additional losses.
机译:有源开关的零电压开关(ZVS)的损耗已成为全桥(FBZVS)转换器的严重限制。过去已经提出了许多技术来将ZVS操作的范围扩展到更宽的范围以及整个操作范围。然而,在这些技术中,以有源开关中的附加传导损耗和辅助部件中的损耗为代价来实现ZVS。本文对各种全范围FBZVS DC-DC转换器的附加损耗进行了分析,并进行了比较评估。闭合形式的表达式是针对设备电流和损耗的平均值得出的。绘制并比较了各种拓扑的损耗曲线。发现分析结果与在500 W,100 kHz原型上执行的实验效率测试一致。结论是,最近提出的新拓扑具有最小的附加损失损失。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号