...
首页> 外文期刊>Otology and neurotology: official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology >Retrospective analysis of early postoperative hearing results obtained after stapedotomy with implantation of a new titanium stapes prosthesis.
【24h】

Retrospective analysis of early postoperative hearing results obtained after stapedotomy with implantation of a new titanium stapes prosthesis.

机译:钛合金pes骨假体植入术后,早期术后听觉结果的回顾性分析。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: To evaluate the early postoperative hearing results of a new titanium stapes prosthesis (K-Piston) implanted in patients with otosclerosis. STUDY DESIGN: A retrospective analysis of preoperative and early postoperative hearing thresholds. SETTING: One tertiary referral and teaching hospital. PATIENTS: Eighteen men and 40 women, mean age 47 years, with otosclerosis. INTERVENTION: Primary stapedotomy. MAIN OUTCOME MEASURE: Main outcome measures were the mean gains in bone-conduction and air-conduction pure-tone thresholds, and pure-tone averages for different frequency combinations. Success and failure of the individual cases were presented using Amsterdam Hearing Evaluation Plots. RESULTS: The overall postoperative air-bone gap for the frequency combination 0.5-1-2-4 kHz was 8.4 (standard deviation: 5.2) dB. In 79% of the patients the postoperative air-bone gap was less than 10 dB. Air-conduction improved even in higher frequencies, while the Carhart effect was not seen in most cases. In three patients a deterioration of bone-conduction was observed ranging from 11 to 16 dB sound pressure level (SPL), and in four patients the gain in air-conduction was insufficient (3-29 dB SPL) to close the preoperative air-bone gap to within 20 dB. CONCLUSION: The new low-weight, full-titanium stapes prosthesis with its slight rough surface and its good mechanical stability and biocompatibility can safely and successfully restore the function of the middle ear when implanted in patients with otosclerosis.
机译:目的:评估一种新的钛骨假体(K-活塞)在耳硬化症患者中的术后早期听力结果。研究设计:术前和术后早期听力阈值的回顾性分析。地点:一家三级转诊和教学医院。患者:18名男性和40名女性,平均年龄47岁,患有耳硬化症。干预:原发性骨切开术。主要观察指标:主要观察指标是骨导和气导纯音阈值的平均增益,以及不同频率组合的纯音平均值。使用阿姆斯特丹听力评估图介绍了个别案例的成功与失败。结果:频率组合0.5-1-2-4 kHz的总体术后气隙为8.4 dB(标准差:5.2)dB。在79%的患者中,术后气隙小于10 dB。即使在更高的频率下,空气传导也有所改善,而在大多数情况下都没有看到Carhart效应。在三名患者中,观察到骨传导的恶化范围为11至16 dB声压级(SPL),而在四名患者中,空气传导的增益不足(3-29 dB SPL)不能闭合术前空气骨间隙在20 dB以内。结论:新型低重量,全钛骨假体具有轻微的粗糙表面,良好的机械稳定性和生物相容性,可以安全,成功地恢复耳硬化症患者植入中耳的功能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号