首页> 外文期刊>Oxidation Communications >TREATMENT OF OILY WASTEWATER VIA FENTON OXIDATION UNITED WITH COAGULATION
【24h】

TREATMENT OF OILY WASTEWATER VIA FENTON OXIDATION UNITED WITH COAGULATION

机译:混凝联合Fenton氧化法处理含油废水。

获取原文
获取原文并翻译 | 示例
           

摘要

This work investigated the degradation of oily wastewater via Fenton process. The effects of H2O2 dosage, Fe2+ dosage and reaction time on chemical oxygen demand (COD) removal are investigated during the oxidation and coagulation processes. The results show that the COD removal reached 53.9% under the optimum condition: H2O2 dosage of 170 mmol/l, Fe2+ dosage of 30 mmol/l and reaction time of 150 min, under which 46.2% COD was removed via oxidation process and 7.7% COD was removed via coagulation process.
机译:这项工作研究了通过Fenton工艺降解含油废水的方法。在氧化和凝聚过程中,研究了H2O2用量,Fe2 +用量和反应时间对化学需氧量(COD)去除的影响。结果表明,在最佳条件下:H2O2用量为170 mmol / l,Fe2 +用量为30 mmol / l,反应时间为150 min时,COD去除率达到53.9%,在此条件下,氧化工艺去除了46.2%的COD,7.7%通过凝结过程去除了化学需氧量。