首页> 外文期刊>Optica applicata >Are traditional methods of balancing accommodation still useful in the modern optometry office? A comparison of methods
【24h】

Are traditional methods of balancing accommodation still useful in the modern optometry office? A comparison of methods

机译:传统的平衡调节方法在现代验光室中仍然有用吗?方法比较

获取原文
获取原文并翻译 | 示例
           

摘要

The goal of this research is to compare the usefulness of both Turville infinity balance (TIB) and Humphriss immediate contrast (HIC) as methods of balancing accommodation. Statistical analysis of test results and practical application of both tests were taken into account. A group of 50 people between 18 to 72 years of age were examined. Balancing the state of accommodation of each eye by the two aforementioned methods was performed after refractive examination and full correction of refractive errors. The examination was carried out by the use of phoropter and optotypes on the LCD monitor. Bland Altman plots were used as a method of statistical analysis. Calculations were made by the use of the programs Excel 2000 and MedCalc. Three variables d, T and H were defined as the differences in spherical lens powers, right and left eye respectively, after monocular refraction (d), after the balance of accommodation by the TIB test (T) and after the balance of accommodation by HIC test (H). The mean difference between TIB and HIC methods for the same individuals was +0.05 (95% limits of agreement: from 0.40 to +0.51 D), the mean difference between the refraction monocular (d) and the TIB method (T) was +0.01 D (95% limits of agreement: 0.48 to +0.50 D), the mean difference between monocular refraction (d) and HIC method (H) was 0.07 D (95% limits of agreement: from-0.56 to +0.69 D). Comparison of the selected methods of balancing accommodation shows that for patients, in whom it can be used, the Turville infinity balance test is a superior method to the Humphriss immediate contrast test.
机译:这项研究的目的是比较Turville无限平衡(TIB)和Humphriss立即对比(HIC)作为平衡住宿方法的有用性。考虑了测试结果的统计分析和两种测试的实际应用。检查了一组18至72岁的50人。在屈光检查和屈光不正的完全矫正之后,通过上述两种方法来平衡每只眼睛的适应状态。该检查是通过在LCD监视器上使用屈光检查仪和验光仪进行的。乏味的奥特曼图被用作统计分析的方法。通过使用程序Excel 2000和MedCalc进行计算。三个变量d,T和H分别定义为单眼屈光后(d),TIB测试适应性平衡后(T)和HIC适应性平衡后的右眼和左眼球面镜屈光度的差异测试(H)。同一个人的TIB和HIC方法之间的平均差异为+0.05(协议的95%限制:从0.40到+0.51 D),屈光单眼(d)和TIB方法(T)之间的平均差异为+0.01 D(95%的协议限制:从-0.56至+0.69 D)(95%的协议限制:0.48至+0.50 D),单眼屈光度(d)和HIC方法(H)之间的平均差为0.07 D(95%的协议限制:从-0.56至+0.69 D)。对所选平衡调节方法的比较表明,对于可以使用调节平衡的患者,Turville无限平衡测试是优于Humphriss立即对比测试的一种方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号