Influence of the quality of tibial plateau alignment on the reproducibility of computer joint space measurement from Lyon schuss radiographic views of the knee in patients with knee osteoarthritis.

机译:膝关节骨关节炎患者的胫骨平台对准质量对计算机关节间隙测量可重复性的影响(来自里昂·舒斯的膝关节影像学检查)。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

RATIONALE: The quality of medial tibial plateau (MT-Plateau) alignment is one of the key elements for accuracy and sensitivity to change of knee radiography in knee osteoarthritis (OA). AIM: To evaluate the influence of the quality of the MT-Plateau alignment on the reproducibility of joint space width (JSW) measurement in knee radiographs. METHODS: One hundred and twenty-seven knee radiographs (99 OA), performed using a standardized radiographic procedure (Lyon schuss (LS) view). Evaluation of the quality of MT-Plateau alignment. Computerized measurement of the JSW, twice, 1-month apart, using a semi-automated and an automated method of measurement. Assessment of the reproducibility of repeated measurements: calculation of intra-observer coefficient of correlation, smallest detectable difference (SDD) and coefficient of variation (CV). RESULTS: MT-Plateau alignment was satisfactory in 99 radiographs (77.9%). Reproducibility was excellent in both satisfactory and non-satisfactory radiographs, irrespective of the method of measurement used. The automated measurement was more reproducible than the semi-automated one (CV 1.15% and 3.23%). SDD and CV were better in satisfactory than in non-satisfactory MT-Plateau aligned radiographs. CONCLUSION: These results confirm that computer measurement of the medial tibio-femoral JSW, from LS digitized radiographs, is highly reproducible, irrespective of the quality of the radiograph. However, the quality of the MT-Plateau alignment influences the reproducibility of JSW measurement. The automated measurement was more reproducible than the semi-automated one.
机译:理由:胫骨平台内侧(MT-Plateau)对齐的质量是对膝骨关节炎(OA)的膝部射线照相术的准确性和敏感性的关键要素之一。目的:通过膝关节X线照片评估MT-高原对位质量对关节间隙宽度(JSW)测量结果可重复性的影响。方法:127膝部X光片(99 OA),使用标准的X线摄影程序(Lyon schuss(LS)视图)进行。评估MT-高原对准的质量。 JSW的计算机化测量,间隔两次,间隔1个月,使用半自动和自动化的测量方法。评估重复测量的可重复性:观察者内部相关系数,最小可检测差异(SDD)和变异系数(CV)的计算。结果:在99张X线片中,MT-高原对位令人满意(77.9%)。无论使用哪种测量方法,在令人满意的和不满意的X射线照片中,重现性均极佳。自动化测量比半自动化测量(CV 1.15%和3.23%)具有更高的可重复性。 SDD和CV在令人满意的情况下比未令人满意的MT-Plateau对准射线照片更好。结论:这些结果证实,无论数字X线片的质量如何,从LS数字化X线片计算机测量内侧股骨股骨JSW均具有很高的重现性。但是,MT-高原比对的质量会影响JSW测量的可重复性。自动测量比半自动测量更可重复。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号