Articular damage caused by metal plugs in a rabbit model for treatment of localized cartilage defects.

机译:用于治疗局部软骨缺损的兔子模型中的金属塞引起的关节损伤。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: Currently, the surgical treatment of localized cartilage defects has limitations. Alternatively, localized cartilage defects may be treated with small biocompatible metal cartilage tacks. Our purpose was to investigate the applicability of defect-size femoral implants. Different bearing materials, cobalt-chromium (CoCr) and oxidized zirconium (OxZr), were tested to evaluate the effect on opposing cartilage quality and osseointegration at different insertion depths. METHODS: In 18 adult female New Zealand White rabbits, a medial femoral condyle defect was filled with either an OxZr or a CoCr implant (slashed circle articulating surface 3.5mm; fixating pin of 9.1mm length), placed flush, 1mm deep or 1mm protruding with respect to the level of the surrounding cartilage. Animals were sacrificed after 4 weeks. Tibial cartilage quality was scored microscopically and osseointegration measured by automated histomorphometry. RESULTS: Considerable articulating cartilage erosion was found in all conditions. Tibial cartilage quality was least compromised when both implants were placed flush compared to deep (P=0.01) or protruding position (P=0.004) and was better for OxZr compared to CoCr (P=0.011) when left protruding, while no differences were found when placed deep of flush. Most bone formation around the fixating pin was observed in a protruding position (P=0.01). In deep position, more bone-implant contact was observed with CoCr compared to OxZr (P=0.02). CONCLUSIONS: OxZr and CoCr implants showed good osseointegration when used as a localized cartilage defect treatment in the rabbit knee; however, opposite cartilage damage was observed in all cases. Placement flush to the surrounding cartilage seems essential and when left protruding OxZr may be less erosive. In conclusion, caution is warranted using small metal implants for the treatment of localized cartilage in the human patient.
机译:目的:目前,局限性软骨缺损的手术治疗存在局限性。或者,可以用小的生物相容性金属软骨钉治疗局部软骨缺损。我们的目的是研究缺损大小的股骨植入物的适用性。测试了不同的轴承材料钴铬(CoCr)和氧化锆(OxZr),以评估在不同插入深度对相反软骨质量和骨整合的影响。方法:在18只成年雌性新西兰白兔中,用OxZr或CoCr植入物(切开的圆形关节表面3.5mm;固定销长9.1mm)填充股内侧con缺损,齐平,深1mm或突出1mm关于周围软骨的水平。 4周后处死动物。用显微镜对胫骨软骨质量进行评分,并通过自动组织形态计量术测量骨整合。结果:在所有情况下均发现了明显的关节软骨侵蚀。与深部(P = 0.01)或突出位置(P = 0.004)齐平放置时,胫骨软骨质量受到的影响最小,左突出时与CoCr相比,OxZr更好(P = 0.011),但无差异当放置在齐平的深处时。在突出位置观察到固定销周围的大部分骨形成(P = 0.01)。在深处,与OxZr相比,CoCr观察到更多的骨-植入物接触(P = 0.02)。结论:OxZr和CoCr植入物在兔膝关节局部软骨缺损治疗中显示出良好的骨整合性。然而,在所有情况下都观察到相反的软骨损伤。放置在与周围软骨齐平的位置似乎很重要,当左突出的OxZr侵蚀较小时。总之,使用小型金属植入物治疗人类患者的局部软骨是必须谨慎的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号