首页> 外文期刊>Osteoarthritis and cartilage >Novel fast semi-automated software to segment cartilage for knee MR acquisitions.
【24h】

Novel fast semi-automated software to segment cartilage for knee MR acquisitions.

机译:新颖的快速半自动软件,可对软骨进行分段以进行膝盖MR采集。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: Validation of a new fast software technique to segment the cartilage on knee magnetic resonance (MR) acquisitions. Large studies of knee osteoarthritis (OA) will require fast and reproducible methods to quantify cartilage changes for knee MR data. In this report we document and measure the reproducibility and reader time of a software-based technique to quantify the volume and thickness of articular cartilage on knee MR images. METHODS: The software was tested on a set of duplicate sagittal three-dimensional (3D) dual echo steady state (DESS) acquisitions from 15 (8 OA, 7 normal) subjects. The repositioning, inter-reader, and intra-reader reproducibility of the cartilage volume (VC) and thickness (ThC) were measured independently as well as the reader time for each cartilage plate. The root-mean square coefficient of variation (RMSCoV) was used as metric to quantify the reproducibility of VC and mean ThC. RESULTS: The repositioning RMSCoV was as follows: VC=2.0% and ThC=1.2% (femur), VC=2.9%and ThC=1.6% (medial tibial plateau), VC=5.5% and ThC=2.4% (lateral tibial plateau), and VC=4.6% and ThC=2.3% (patella). RMSCoV values were higher for the inter-reader reproducibility (VC: 2.5-8.6%) (ThC: 1.9-5.2%) and lower for the intra-reader reproducibility (VC: 1.6-2.5%) (ThC: 1.2-1.9%). The method required an average of 75.4min per knee. CONCLUSIONS: We have documented a fast reproducible semi-automated software method to segment articular cartilage on knee MR acquisitions.
机译:目的:验证一种新的快速软件技术,以在膝部磁共振(MR)采集中分割软骨。膝关节骨关节炎(OA)的大型研究将需要快速且可重现的方法来量化膝关节MR数据的软骨变化。在本报告中,我们记录并测量了基于软件的技术的可重复性和阅读器时间,以量化膝盖MR图像上的关节软骨的体积和厚度。方法:该软件在一组重复的矢状三维(3D)双回波稳态(DESS)采集中进行了测试,这些采集来自15位(8 OA,7位正常)受试者。分别测量每个软骨板的软骨体积(VC)和厚度(ThC)的重定位,阅读器内和阅读器内重现性,以及阅读器时间。均方根变异系数(RMSCoV)被用作量化VC和平均ThC的可重复性的指标。结果:重新定位RMSCoV如下:VC = 2.0%,ThC = 1.2%(股骨),VC = 2.9%,ThC = 1.6%(胫骨内侧平台),VC = 5.5%,ThC = 2.4%(胫骨外侧平台) ),VC = 4.6%,ThC = 2.3%(pat骨)。阅读器间再现性的RMSCoV值较高(VC:2.5-8.6%)(ThC:1.9-5.2%),阅读器内部再现性的RMSCoV值较低(VC:1.6-2.5%)(ThC:1.2-1.9%) 。该方法平均每膝需要75.4分钟。结论:我们已经记录了一种可快速重现的半自动化软件方法,该方法可在膝部MR采集中分割关节软骨。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号