Diagnostic accuracy and variability of autorefraction by the Tracey Visual Function Analyzer and the Shin-Nippon NVision-K 5001 in relation to subjective refraction.

机译:Tracey视觉功能分析仪和Shin-Nippon NVision-K 5001的自动折射的诊断准确性和变异性与主观折射有关。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To determine the accuracy of distance autorefractions obtained by two 'open field' devices, the Tracey Visual Function Analyzer and the Shin-Nippon NVision-K 5001, by comparison with subjective refraction. METHODS: Both eyes of 50 healthy phakic participants underwent subjective refraction. Autorefractions were then performed on undilated pupils using the Tracey and a modified Shin-Nippon autorefractor and these were repeated within 50 days. Agreement with subjective refraction was calculated for sphere, mean spherical equivalent (MSE) and cylindrical vectors J(0) and J(45). Intratest and intertest variability were also evaluated. RESULTS: The mean age of the participants was 37.4 years. Subjective refraction MSE ranged from -6.25 D to +3.62 D, mean -0.49 D +/- 1.79 D. Bias between subjective refraction and Tracey was -0.001 D, +0.045 D, +0.017 D, and -0.015 D for sphere, MSE, J(0) and J(45) respectively; these were not significant. Bias between subjective refraction and Shin-Nippon was +0.004 D, +0.033 D, +0.106 D, and -0.021 D; only the J(0) vector was significantly different (p < 0.0001) although this difference was small. Intratest variability for Tracey was low, measured at 0.189 D for sphere and 0.178 for MSE, and for the Shin-Nippon 0.099 D and 0.086 D respectively. Tracey intertest variability revealed small, statistically significant bias for sphere and MSE (+0.071 D and +0.070 D, p = 0.011, 0.013). Shin-Nippon reproducibility showed no significant bias. CONCLUSIONS: Autorefraction measurements captured by both the Tracey and Shin-Nippon devices agree well with subjective refraction. The Shin-Nippon shows lower intratest variability.
机译:目的:通过比较主观折射,确定由Tracey视觉功能分析仪和Shin-Nippon NVision-K 5001这两个“开放视野”设备获得的距离自动折射的准确性。方法:50名健康晶状体参与者的两只眼睛都进行了主观验光。然后使用Tracey和改良的Shin-Nippon自动折射仪对未散瞳进行自动折射,并在50天内重复进行。计算球体,平均球当量(MSE)和圆柱向量J(0)和J(45)与主观折射的一致性。还评估了测试内和测试间的变异性。结果:参与者的平均年龄为37.4岁。 MSE的主观折射MSE范围为-6.25 D至+3.62 D,平均值为-0.49 D +/- 1.79D。对于球体,MSE,主观折射与Tracey之间的偏差为-0.001 D,+ 0.045 D,+ 0.017 D和-0.015 D ,分别为J(0)和J(45);这些并不重要。主观折射和新日本制之间的偏差为+0.004 D,+ 0.033 D,+ 0.106 D和-0.021 D;尽管此差异很小,但只有J(0)矢量有显着差异(p <0.0001)。特蕾西(Tracey)的测试内变异性较低,对于球体为0.189 D,对于MSE为0.178 D,对于新日本公司,分别为0.099 D和0.086D。跟踪测试间的差异显示球形和MSE的统计偏差较小(+0.071 D和+0.070 D,p = 0.011、0.013)。 Shin-Nippon的再现性没有明显的偏差。结论:Tracey和Shin-Nippon设备捕获的自动折射测量值与主观折射非常吻合。 Shin-Nippon显示出较低的测试内变异性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号